Si5345-44-42-D-RM
184
Rev. 1.0
Si5342
Register 0x0046-0x0049 Out of Frequency Set Threshold
Reg Address
Bit Field
Type
Name
Description
0x0046
7:0
R/W
OOF0_SET_THR
OOF Set threshold. Range is up to
500 ppm in steps of 1/16 ppm.
0x0047
7:0
R/W
OOF1_SET_THR
OOF Set threshold. Range is up to
500 ppm in steps of 1/16 ppm.
0x0048
7:0
R/W
OOF2_SET_THR
OOF Set threshold. Range is up to
500 ppm in steps of 1/16 ppm.
0x0049
7:0
R/W
OOF3_SET_THR
OOF Set threshold. Range is up to
500 ppm in steps of 1/16 ppm.
Register 0x004A-0x004D Out of Frequency Clear Threshold
Reg Address
Bit Field
Type
Name
Description
0x004A
7:0
R/W
OOF0_CLR_THR
OOF Clear threshold. Range is up to
500 ppm in steps of 1/16 ppm.
0x004B
7:0
R/W
OOF1_CLR_THR
OOF Clear threshold. Range is up to
500 ppm in steps of 1/16 ppm.
0x004C
7:0
R/W
OOF2_CLR_THR
OOF Clear threshold. Range is up to
500 ppm in steps of 1/16 ppm.
0x004D
7:0
R/W
OOF3_CLR_THR
OOF Clear threshold. Range is up to
500 ppm in steps of 1/16 ppm.
Register 0x004E -0x04F OOF Detection Windows
Reg Address
Bit Field
Type
Setting Name
Description
0x004E
2:0
R/W
OOF0_DETWIN_SEL
Values calculated by CBPro
0x004E
6:4
R/W
OOF1_DETWIN_SEL
0x004F
2:0
R/W
OOF2_DETWIN_SEL
0x004F
6:4
R/W
OOF3_DETWIN_SEL
Register 0x0051-0x0054 Fast Out of Frequency Set Threshold
Reg Address
Bit Field
Type
Name
Description
0x0051
3:0
R/W
FAST_OOF0_SET_THR
(1+ value) x 1000 ppm
0x0052
3:0
R/W
FAST_OOF1_SET_THR
(1+ value) x 1000 ppm
0x0053
3:0
R/W
FAST_OOF2_SET_THR
(1+ value) x 1000 ppm
0x0054
3:0
R/W
FAST_OOF3_SET_THR
(1+ value) x 1000 ppm