Si5345-44-42-D-RM
Si5344
Rev. 1.0
167
Register 0x053D
Reg Address
Bit Field
Type
Name
Description
0x053D
4:0
R/W
HSW_COARSE_PM_LEN
Set by CBPro.
Register 0x053E
Reg Address
Bit Field
Type
Name
Description
0x053E
4:0
R/W
HSW_COARSE_PM_DLY
Set by CBPro.
Register 0x053F
Reg Address
Bit Field
Type
Name
Description
0x053F
1
R/O
HOLD_HIST_VALID
1 = there is enough historical fre-
quency data collected for valid
holdover.
0x053F
2
R/O
FASTLOCK_STATUS
1 = PLL is in Fast Lock operation
Register 0x0588 Hitless Switching Length
Reg Address
Bit Field
Type
Setting Name
Description
0x0588
3:0
R/W
HSW_FINE_PM_LEN
Set by CBPro.
Register 0x0589 - 0x058A PFD Enable Delay
Reg Address
Bit Field
Type
Setting Name
Description
0x0589
7:0
R/W
PFD_EN_DELAY
Set by CBPro.
0x058A
12:8
R/W
PFD_EN_DELAY
Register 0x059B Holdover Exit
Reg Address
Bit Field
Type
Setting Name
Description
0x059B
6
R/W
HOLDEXIT_BW_SEL0
Set by CBPro.
See HOLDEXIT_BW_SEL1