Si5345-44-42-D-RM
202
Rev. 1.0
Si5342
14.5.4. Page 3 Registers Si5342
The N dividers are interpolative dividers that are used as output dividers that feed into the R dividers. ClockBuilder
Pro calculates the correct values for the N-dividers.
This bit is provided so that all of the N0 divider bits can be changed at the same time. First, write all of the new
values to the divider, then set the update bit.
Register 0x0302-0x0307 N0 Numerator
Reg Address
Bit Field
Type
Name
Description
0x0302
7:0
R/W
N0_NUM
44-bit Integer Number
0x0303
15:8
R/W
N0_NUM
0x0304
23:16
R/W
N0_NUM
0x0305
31:24
R/W
N0_NUM
0x0306
39:32
R/W
N0_NUM
0x0307
43:40
R/W
N0_NUM
Register 0x0308-0x030B N0 Denominator
Reg Address
Bit Field
Type
Name
Description
0x0308
7:0
R/W
N0_DEN
32-bit Integer Number
0x0309
15:8
R/W
N0_DEN
0x030A
23:16
R/W
N0_DEN
0x030B
31:24
R/W
N0_DEN
Register 0x0338
Reg Address
Bit Field
Type
Name
Description
0x030C
0
R/W
N0_UPDATE
Set this bit to update the N0 divider
Table 59. Register that Follows the N0_NUM and N0_DEN Definitions
Register Address
Description
Size
Same as Address
0x030D-0x0312
N1 Numerator
44-bit Integer Number
0x0302-0x0307
0x0313-0x0316
N1 Denominator
32-bit Integer Number
0x0308-0x030B