Overview of Alarms
11/2006
NCK alarms
2-364
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
20061
Channel %1 axis %2 cannot be traversed as orientation axis
Parameters:
%1 = Channel number
%2 = Axis name
Definitions:
The axis is not an orientation axis and can therefore not be traversed as an orientation axis in JOG
mode.
Reaction:
Alarm display.
Remedy:
Register the axis as an orientation axis.
Program
Continuation:
Clear alarm with the Delete key or NC START.
20062
Channel %1 axis %2 already active
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Definitions:
The displayed axis is already traversing as a machine axis. Therefore, it cannot be operated as a
geometry axis.
Traversing of an axis can take place in JOG mode through 2 different interfaces.
1. as a geometry axis: via the channel-specific interface DB 21 - DB 28, DBX12.6 or DBX12.7
2. as a machine axis: via the axis-specific interface DB 31 - DB 48 DBX8.6 or DBX8.7
With the standard machine control panel, it is not possible to operate an axis as machine axis and
geometry axis at the same time.
Reaction:
Alarm display.
Remedy:
Do not start the geometry axis until the traversing motion as machine axis has been concluded.
Program
Continuation:
Clear alarm with the Delete key or NC START.
20063
Channel %1 axis %2 orientation axes cannot be traversed without
transformation
Parameters:
%1 = Channel number
%2 = Axis name
Definitions:
An attempt was made to move an orientation axis in JOG mode without an active orientation
transformation.
Reaction:
Alarm display.
Remedy:
Activate an orientation transformation.
Program
Continuation:
Clear alarm with the Delete key or NC START.
20064
Channel %1 axis %2 selection of several axes with an active taper angle
is not permitted.
Parameters:
%1 = Channel number
%2 = Axis name, spindle number
Definitions:
With an active taper angle, only one geometry axis at the time can be traversed in JOG mode by
pressing traversing keys. Simultaneous traversing of a geometry axis as a machine axis is not
permitted either.
Reaction:
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Starting the geometry axis only if traversing of the other geometry axis or machine axis completed.
Program
Continuation:
Clear alarm with the RESET key in all channels. Restart part program.