Overview of Alarms
11/2006
NCK alarms
2-146
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
10930
Channel %1 block %2 interpolation type not allowed in stock removal
contour
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The following types of interpolation are allowed in the contour program for stock removal: G00, G01,
G02, G03, CIP, CT
Reaction:
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
In the contour subroutine, program only path elements that consist of straight lines and arcs.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
10931
Channel %1 block %2 incorrect stock removal contour
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The following errors occurred in the subroutine for the contour during stock removal:
- Full circle
- Overlapping contour elements
- Wrong start position
Reaction:
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
The errors listed above must be corrected in the subroutine for the stock removal contour.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
10932
Channel %1 block %2 preparation of contour has been restarted
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The first contour preparation/contour decoding run must be terminated with EXECUTE.
Reaction:
Local alarm reaction.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program the keyword EXECUTE to terminate the contour preparation in the part program before again
calling up contour segmentation (keyword CONTPRON).
Program
Continuation:
Clear alarm with the RESET key. Restart part program