NCK alarms
11/2006
Overview of Alarms
2-85
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
6690
Cycles from NC card cannot be copied to the passive file system.
Definitions:
There is not enough space in the file system that the directories specified in the
$PCMCIA_FUNCTION_MASK can be copied from the NC card to the passive file system.
Reaction:
Alarm display.
Remedy:
Delete data in the file system.
Program
Continuation:
Clear alarm with the Delete key or NC START.
6691
Cycles from the passive file system cannot be saved on the NC card
Definitions:
There is not enough space on the NC card that the directories specified in the
$PCMCIA_FUNCTION_MASK can be saved. It is possible that cycles are lost during the next booting.
Reaction:
Alarm display.
Remedy:
Delete data on the NC card or delete cycles not required.
Program
Continuation:
Clear alarm with the Delete key or NC START.
6692
Cycle %1 lost
Parameters:
%1 = Name of cycle
Definitions:
A cycle has been changed and due to a power failure, the backup on the PC card could not be
terminated properly. The cycle is lost.
Reaction:
NC not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Import the cycle again.
Program
Continuation:
Switch control OFF - ON.
6693
File %1 lost
Parameters:
%1 = Name of file
Definitions:
Due to a power failure, a file change could not be terminated properly. The file is lost.
Reaction:
NC not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Import the file again.
Program
Continuation:
Switch control OFF - ON.
6698
Unknown NC card (%1/%2). Writing not possible.
Parameters:
%1 = actManufactorCode (manufacturer code read by the card)
%2 = actDeviceCode (memory code read by the card)
Definitions:
The NC card cannot be accessed because a valid write algorithm is not available for the flash memory.
Reaction:
Alarm display.
Remedy:
Use a compatible NC card or enter the new manufacturer code/device code in MD
$MN_PERMISSIVE_FLASH_TAB after consultation with SIEMENS.
Program
Continuation:
Clear alarm with the Delete key or NC START.