11/2006
List of Action Numbers
3-847
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), Edition 11/2006
No. 86
No. 87
No. 88
No. 89
No. 90
No. 91
Explanation
Activate an "ASUB" user interrupt. Is only executed if the channel is in the READY status
(VDI signal: ASUB interface, digital-analog interface).
Cause
See No. 10
Remedy
-
Explanation
Perform an "ASUB" user interrupt (VDI signal: ASUB interface, digital-analog interface;
for further actions see 10, 11, 12, 85, 86)
Cause
-
Remedy
-
Explanation
Start program processing (VDI signal: Mode group stop)
Cause
-
Remedy
-
Explanation
Activate all machine data with the attribute (NEW_CONF) (NC_block: NEW_CONF)
Cause
-
Remedy
-
Explanation
Activate all machine data with the attribute (NEW_CONF) (NC_block: NEW_CONF with
block search)
Cause
-
Remedy
-
Explanation
Start continuation of interpreter processing (internal preprocessing stop)
Cause
-
Remedy
-