16792
Channel %1 block %2 too many couplings for axis/spindle %3
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
For the specified axis/spindle, more master axes/spindles have been defined than are allowed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
16793
Channel %1 block %2 coupling of axis %3 prohibits transformation
change
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
The specified axis is a slave axis in a transformation grouping. When the coupling is switched on, the
transformation cannot be changed to another one.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program. Switch off coupling(s) of this axis before changing transformation or do not
change the transformation.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
16794
Channel %1 block %2 coupling of axis/spindle %3 prohibits reference
point approach
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
The specified axis is a (gantry) slave axis and cannot therefore approach the reference point.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program. Switch off coupling(s) of this axis before reference point approach or do not
reference. A gantry slave axis cannot reference for itself.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
16795
Channel %1 block %2 string cannot be interpreted
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A coupling has been switched on in which a non-interpretable string has been written (e.g. block
change behavior).
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.