SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
17620
Channel %1 block %2 approaching fixed point for transformed axis %3
not possible
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
In the displayed block, an axis is programmed for the fixed point approach (G75) that is involved in the
active transformation. Fixed point approach is not performed with this axis!
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Remove G75 instruction from the part program block or previously deselect transformation with
TRAFOOF.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
17630
Channel %1 block %2 referencing for transformed axis %3 not possible
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
In the displayed block, an axis is programmed for reference point approach (G74) that is involved in
the active transformation. Reference point approach is not performed with this axis!
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Remove G74 instruction, or the machine axes involved in transformation, from the part program block
or previously deselect the transformation with TRAFOOF.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
17640
Channel %1 block %2 spindle operation for transformed axis %3 not
possible
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
The axis programmed for the spindle operation is involved in the current transformation as geometry
axis. This is not allowed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
First switch off the transformation function.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.