NCK alarms
11/2006
Overview of Alarms
2-527
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
61257
Channel %1 block %2: incomplete installation of counterspindle
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Start-up of the counterspindle is incomplete.
Alarm triggered by following cycle: F_SUB_SP.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check display machine data 9803, 9851, 9852, 9853 and 9854 .
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61258
Channel %1 block %2: set parameters for counterspindle chuck in the
spindle image
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The parameters for the counterspindle chuck have not been set in the spindle view.
Alarm triggered by following cycle: F_SUB_SP.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Specify parameters "ZL1", "ZL2" and "ZL3" in mask "Tools work offset" > "Spindles".
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61259
Channel %1 block %2: program contains new machining steps from
ShopMill %4
Parameters:
%1 = Channel number
%2 = Block number, label
%4 = ShopMill version
Definitions:
The program has been created with a ShopMill version that is higher than the existing one.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Delete the machining step and reprogram machining if required.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61260
Channel %1 block %2: program contains new machining steps from
ShopTurn %4
Parameters:
%1 = Channel number
%2 = Block number, label
%4 = ShopTurn version
Definitions:
The program has been created with a ShopMill version that is higher than the existing one.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Delete the machining step and reprogram machining if required.
Program
Continuation:
Clear alarm with the RESET key. Restart part program