
Parameterization
03.2010
6SE7087-6QX70 (Version AL) Siemens AG
5-36
Compendium Motion Control
SIMOVERT MASTERDRIVES
5.5.2.3
Creating a parameter set
With menu
File
New
...
you can create a new drive for
parameterization (see Fig. 5-12). The system creates a download file
(*.dnl), in which the drive characteristic data (type, device version) are
stored. You can create the download file on the basis of an empty
parameter set or the factory setting.
Fig. 5-12
Creating a new drive
Based on factory setting:
♦
The parameter list is preassigned with the factory setting values
Empty parameter set:
♦
For compilation of individually used parameters
If the parameters of a parameter set that has already been created
have to be changed, this can be done by calling the corresponding
download file via the “
File
Open”
menu function. The last four drives
can be opened via
“Parameter sets last dealt with”
.
When you create a new drive, the window "Drive Properties" (Fig. 5-13)
opens. Here you must enter the following data:
♦
In dropdown list box "Device type", select the type of device (e.g.
MASTERDRIVES MC). You can only select the devices stored.
♦
In dropdown list box "Device version", you can select the software
version of the device. You can generate databases for (new)
software versions that are not listed when you start online
parameterization.
♦
You must only specify the bus address of the drive during online
operation (switchover with button Online/Offline)
Содержание simovert masterdrives
Страница 1: ...Compendium Edition AN simovert masterdrives Motion Control ...
Страница 2: ......
Страница 13: ......
Страница 197: ...Parameterizing Steps 08 2012 6SE7087 6QX70 Version AN Siemens AG 6 32 Compendium Motion Control SIMOVERT MASTERDRIVES ...
Страница 199: ...Parameterizing Steps 08 2012 6SE7087 6QX70 Version AN Siemens AG 6 34 Compendium Motion Control SIMOVERT MASTERDRIVES ...
Страница 201: ...Parameterizing Steps 08 2012 6SE7087 6QX70 Version AN Siemens AG 6 36 Compendium Motion Control SIMOVERT MASTERDRIVES ...
Страница 203: ...Parameterizing Steps 08 2012 6SE7087 6QX70 Version AN Siemens AG 6 38 Compendium Motion Control SIMOVERT MASTERDRIVES ...
Страница 205: ...Parameterizing Steps 08 2012 6SE7087 6QX70 Version AN Siemens AG 6 40 Compendium Motion Control SIMOVERT MASTERDRIVES ...
Страница 207: ...Parameterizing Steps 08 2012 6SE7087 6QX70 Version AN Siemens AG 6 42 Compendium Motion Control SIMOVERT MASTERDRIVES ...
Страница 209: ...Parameterizing Steps 08 2012 6SE7087 6QX70 Version AN Siemens AG 6 44 Compendium Motion Control SIMOVERT MASTERDRIVES ...
Страница 947: ...08 2012 Siemens AG 6SE7087 6QX70 Version AN SIMOVERT MASTERDRIVES Compendium Motion Control Function Diagrams ...
Страница 1160: ...03 2010 Siemens AG 6SE7087 6QX70 Version AL SIMOVERT MASTERDRIVES Compendium Motion Control General parameter list ...
Страница 1416: ...03 2010 Siemens AG 6SE7087 6QX70 Version AL SIMOVERT MASTERDRIVES Compendium Motion Control Connector list ...
Страница 1446: ...03 2010 Siemens AG 6SE7087 6QX70 Version AL SIMOVERT MASTERDRIVES Compendium Motion Control Binector list ...
Страница 1466: ...03 2010 Siemens AG 6SE7087 6QX70 Version AL SIMOVERT MASTERDRIVES Compendium Motion Control List of function data set parameters ...
Страница 1471: ...03 2010 Siemens AG 6SE7087 6QX70 Version AL SIMOVERT MASTERDRIVES Compendium Motion Control List of binector data set parameters ...
Страница 1535: ......
Страница 1536: ......
Страница 1537: ......
Страница 1538: ......
Страница 1539: ......
Страница 1540: ......
Страница 1541: ......
Страница 1542: ......
Страница 1543: ......
Страница 1546: ......