![Siemens simovert masterdrives Скачать руководство пользователя страница 1373](http://html.mh-extra.com/html/siemens/simovert-masterdrives/simovert-masterdrives_compendium_3781711373.webp)
Parameter
Description
Data
Read/write
U660*
Rel Correct
2660
INDEX 1:
1 = Enable of position correction
INDEX 2:
1 = Enable of referencing
index1: 0
Min: 0
Max: 1
Unit: -
Indices: 2
Type: O2
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U661*
Mode PosCorr
2661
The parameter determines the effective direction of
position correction.
Value 0 : Means that the axis is not the one which is
transporting
the material with the printing index.
Position correction is made in positive direction.
Value 1 : Means that the axis is the one which is
transporting
the material with the printing index
Position correction is made in the negative
direction.
This parameter makes allowance for the fact that
depending on whether the printing index scanning takes
place in front of or behind the drive, it is necessary to
brake briefly and decelerate briefly, to compensate for
positive displacement.
Function diagram [836.5]
Init: 0
Min: 0
Max: 1
Unit: -
Indices: -
Type: O2
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U662
SetPos PosCorr
2662
If the parameter U664 is set to the value zero, parameter
U662 is used as the reference position.
Position correction operates as follows:
With a positive edge at control bit "Start position
correction" (U666), the difference between reference
position and the measured actual position is determined
upon occurrence of the printing index. This difference is
conveyed to the position correction and reduced with the
correction speed indicated at U667. U661 defines whether
the correction direction is positive or negative.
Function diagram [836.4]
Init: 0
Min: -
2147483648
Max:
2147483647
Unit: -
Indices: -
Type: I4
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U663*
S.SetPos var.
2663
The parameter defines the source for the reference
position of position correction if this is specified by a
connector.
Function diagram [836.3]
Init: 0
Unit: -
Indices: -
Type: L2 ,K
,K
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
- Operation enabled
U664*
Corr'n Type
2664
Correction type for specification of the reference position
of position correction.
Value 0 = means that the reference position for position
correction is specified via U662 as a fixed value.
Value 1 = means that the reference position for position
correction is specified via a connector. The
source
for the connector is defined in U663.
Function diagram [836.4]
Init: 0
Min: 0
Max: 1
Unit: -
Indices: -
Type: O2
Menus:
- Parameter menu
+ Technology
+ Synchronism
- Upread/free access
Changeable in:
- Ready to switch on
213
Siemens AG 6SE7087-6QX70 (Edition AL)
SIMOVERT MASTERDRIVES Compendium Motion Control
Содержание simovert masterdrives
Страница 1: ...Compendium Edition AN simovert masterdrives Motion Control ...
Страница 2: ......
Страница 13: ......
Страница 197: ...Parameterizing Steps 08 2012 6SE7087 6QX70 Version AN Siemens AG 6 32 Compendium Motion Control SIMOVERT MASTERDRIVES ...
Страница 199: ...Parameterizing Steps 08 2012 6SE7087 6QX70 Version AN Siemens AG 6 34 Compendium Motion Control SIMOVERT MASTERDRIVES ...
Страница 201: ...Parameterizing Steps 08 2012 6SE7087 6QX70 Version AN Siemens AG 6 36 Compendium Motion Control SIMOVERT MASTERDRIVES ...
Страница 203: ...Parameterizing Steps 08 2012 6SE7087 6QX70 Version AN Siemens AG 6 38 Compendium Motion Control SIMOVERT MASTERDRIVES ...
Страница 205: ...Parameterizing Steps 08 2012 6SE7087 6QX70 Version AN Siemens AG 6 40 Compendium Motion Control SIMOVERT MASTERDRIVES ...
Страница 207: ...Parameterizing Steps 08 2012 6SE7087 6QX70 Version AN Siemens AG 6 42 Compendium Motion Control SIMOVERT MASTERDRIVES ...
Страница 209: ...Parameterizing Steps 08 2012 6SE7087 6QX70 Version AN Siemens AG 6 44 Compendium Motion Control SIMOVERT MASTERDRIVES ...
Страница 947: ...08 2012 Siemens AG 6SE7087 6QX70 Version AN SIMOVERT MASTERDRIVES Compendium Motion Control Function Diagrams ...
Страница 1160: ...03 2010 Siemens AG 6SE7087 6QX70 Version AL SIMOVERT MASTERDRIVES Compendium Motion Control General parameter list ...
Страница 1416: ...03 2010 Siemens AG 6SE7087 6QX70 Version AL SIMOVERT MASTERDRIVES Compendium Motion Control Connector list ...
Страница 1446: ...03 2010 Siemens AG 6SE7087 6QX70 Version AL SIMOVERT MASTERDRIVES Compendium Motion Control Binector list ...
Страница 1466: ...03 2010 Siemens AG 6SE7087 6QX70 Version AL SIMOVERT MASTERDRIVES Compendium Motion Control List of function data set parameters ...
Страница 1471: ...03 2010 Siemens AG 6SE7087 6QX70 Version AL SIMOVERT MASTERDRIVES Compendium Motion Control List of binector data set parameters ...
Страница 1535: ......
Страница 1536: ......
Страница 1537: ......
Страница 1538: ......
Страница 1539: ......
Страница 1540: ......
Страница 1541: ......
Страница 1542: ......
Страница 1543: ......
Страница 1546: ......