Copyright © Siemens AG 2010. All rights reserved.
Page
60
ERTEC 400 Manual
Technical data subject to change
Version 1.2.2
PME_REG
R/W
Addr.: 0x4000_2624
Default: 0x0000_0000
Description
Power management event PME
Bit No.
Name
Description
31:1
----
Reserved
0
PME
Power management event.
If this bit is set (rising edge), the PCI signal PME_N can be activated.
However, this requires that the PME_ENABLE bit be set in the power
management configuration register of the AHB-PCI bridge (see /3/).
QVZ_AHB_ADR
R
Addr.: 0x4000_2628
Default: 0x0000_0000
Description
Address of incorrect addressing on multilayer AHB
Bit No.
Name
Description
31:0
QVZ_AHB_ADR
Address
QVZ_AHB_CTRL
R
Addr.: 0x4000_262C
Default: 0x0000_0000
Description
Control signals of incorrect addressing on multilayer AHB
Bit No.
Name
Description
31:7
----
Reserved
6:4
HBURST
HBURST
3:1
HSIZE
HSIZE
0
HWRITE
HWRITE
0: HREAD
1: HWRITE
QVZ_AHB_M
R
Addr.: 0x4000_2630
Default: 0x0000_0000
Description
Master identifier of an incorrect addressing on the multilayer AHB
Bit No.
Name
Description
31:3
----
Reserved
2
QVZ_AHB_IRT
IRT
1
QVZ_AHB_LBU/PCI
LBU/PCI
0
QVZ_AHB_ARM946
ARM946
QVZ_APB_ADR
R
Addr.: 0x4000_2634
Default: 0x0000_0000
Description
Address of incorrect addressing on AHB
Bit No.
Name
Description
31:0
QVZ_APB_ADR
Address
QVZ_EMIF_ADR
R
Addr.: 0x4000_2638
Default: 0x0000_0000
Description
Address that leads to timeout on EMIF
Bit No.
Name
Description
31:0
QVZ_EMIF_ADR
Address