an overall duration of five hours truncates the last interval duration to two hours.
The latest value for the specified end time is midnight (24:00).
Your start time must be before the end time and after midnight, and the period
over which incremental energy is accumulated cannot include midnight. This is
because your meter’s start and end times are defined relative to midnight.
Start: 6AM, End:
12AM, interval: 3 hrs
Incremental energy accumulates from 6AM to midnight in intervals of 3
hours.
Start: 6AM, End:
2AM, interval: 3 hrs
Incremental energy will not function. End time must be after start time and
before or equal to midnight.
Incremental energy helps provide information for analyzing energy and power
usage against present or future utility rates, and is useful for measuring energy
consumption by shift or for a specific process.
When configuring incremental energy, shorter incremental energy periods provide
more granular data which can make the data easier to use for comparison
purposes.
Incremental energy example
•
Start time: 8AM or 08:00
•
End time: 12AM or 24:00
•
Interval: 420 minutes (7 hours)
A. First interval (08:00 to 15:00)
B. Second interval (15:00 to 22:00)
C. Third interval (22:00 to 24:00)
The first incremental energy interval is from 8AM (start time) to 3PM, and is 7
hours long. The second incremental energy interval is from 3PM to 10PM, and is
also 7 hours long. The third interval is from 10PM to 12AM, and is only 2 hours
long because 12AM is the specified end time. These intervals repeat every 24
hours until the configuration is changed or incremental energy feature is disabled.
Configuring incremental energy using ION Setup
You can configure incremental energy using ION Setup.
1. Start ION Setup.
2. Open the Setup Assistant for your meter.
3. Navigate to
Energy Applications > Incremental Energy
.
4. Select
Status
and click
Edit
. The
Incremental Energy Setup
screen is
displayed.
5. Select
Enable
to display parameters for configuration.