A-1. Menu map
•
[CAL]
key:
Pressing the
[CAL]
key moves to the next menu in the current hierarchy.
( in the diagram below)
•
[O/T]
key:
Pressing the
[O/T]
key moves the current hierarchy to the menu of one hierarchy down.
( in the diagram below) When no menu exists in the hierarchy below, this command is fixed.
•
[POWER]
key: Pressing the
[POWER]
key returns the current hierarchy to the menu of one hierarchy up.
(
in the diagram below) (Pressing the
[POWER]
key and holding it down returns the interface
directly to the mass display.)
SEtwin|
SEtwin-
Stnd
ConvECt
Hi-Stb
FunC. SEL
CAL
E CAL
E tESt
i CAL
*1
i tESt
*1
Executing alternative calibration method
Span Calibration (external weight)
Calibration test (external weight)
Span Calibration (built-in weight)
Calibration test (built-in weight)
Zero tracking function
On
#
Off
Stability detection band
1 count
#
5 count
10 count
Stability Mark Lighting Timing
For accuracy measurement
#
For fast (quick) measurement
Preset or delete units of measurement
Preset
#
/ delete g unit
Preset / delete
#
mg unit
Preset
#
/ delete
% unit
Preset
#
/ delete
piece counting unit
Preset
#
/ delete
ct unit
Preset / delete
#
solid specific gravity measurement
Preset / delete
#
liquid density measurement
Preset / delete
#
monme unit
Preset / delete
#
Lb unit
Preset / delete
#
Oz unit
Preset / delete
#
Ozt unit
Preset / delete
#
HongKong tael unit
Preset / delete
#
Singapore tael unit
Preset / delete
#
Taiwan tael unit
Preset / delete
#
Malaysia tael unit
Preset / delete
#
Chinese tael unit
Preset / delete
#
dwt unit
Preset / delete
#
GN unit
Preset / delete
#
Mesghal unit
Preset / delete
#
Baht unit
Preset / delete
#
Tola unit
Preset / delete
#
Parts pound unit
0.0000
i CAL (Ex.)
Mass Display
WindowsDirect Setting (Down)
WindowsDirect Setting (Right)
Standard mode
#
Anti-convection mode
High-stability mode
Mass Display
Executing preset calibration method
(Displays the preset calibration method.)
Mass Dis
Mass Display
Mass Display
St. b1 t (Ex.)
Display current condition settings.
Mass Display
Mass Display
Mass Display
Mass Display
Mass Display
Pouring
normL. Env
StAbL. Env
UnStb. Env
Pouring mode
For normal environment
For very stable environment
For unstable environment
Mass Display
bAnd: 1
b-1
b-5
b-10
Stb SiGn
ACCUrACY
FASt
trC: on
trC-on
trC-oF
Unit. SEL
U -
U -
U -
U -
U -
U -
U -
U -
U -
U -
U -
U -
U -
U -
U -
U -
U -
U -
U -
U -
U -
U -
g
mg
%
PCS
ct
,d
d
mom
*4
Lb
*4
Oz
*4
Ozt
*4
HK
*4
SporE
*4
TiwAn
*4
mAL
*4
ChinA
*4
dwt
*4
GN
*4
m
*4
b
*4
t
*4
o
*4
Autoprint function
On
Off
#
AtPrt: on
Ap-on
Ap-oF
Interval timer setting
int
*1,*5
AdiSP: on
Ad-on
Ad-oF
Bar graph display setting
On
#
Off
*1 AUW-D, AUW, AUX series only
*2 AUW series only
*3 AUW-D, AUW series only
#
Default settings
*4 These units cannot be selected in some countries for legal reason.
*4, *5 These units are not available in a verified balance as a legal measuring instrument in the EU.
Continued
(
)
(
)
(
)
(
)
(
)
(
(
(
)
(
(
)
(
(
Continued
( in brackets after the menu item shows reference section number)