95
No
Abbr.
Function description
Control
mode
Setting
range
Unit
PC19 COP2
Alarm history clear option and overload early warning option
0 0 y x
x
:
Alarm history clear option
0
:
does not clear
1
:
to clear the histories after power off once and restart
y
:
overload pre-warn option
0
:
invalid
1
:
to stop the motor when the early warning occurred
Pt, Pr
S,T
0000h
~0011h
-
PC20
SNO
Communication device number
To set different device number for varied devices is necessary.
If two drives occupy the same number, the communication
could not be performed.
Pt, Pr
S,T
1
~32
-
PC21
CMS
Communication mode option
0 0 0 x
x
:
communication reply delay time
0
:
reply within 1 ms
1
:
reply after 1 ms
Pt, Pr
S,T
0000h
~0011h
-
PC22
BPS
Communication protocol option
0
0
y
x
x
:
protocol option
0
:
7 data bit
,
No parity
,
2 stop bit (Modbus
,
ASCII Mode)
1
:
7 data bit
,
Even parity
,
1 stop bit (Modbus
,
ASCII Mode)
2
:
7 data bit
,
Odd parity
,
1 stop bit (Modbus
,
ASCII Mode)
3
:
8 data bit
,
No parity
,
2 stop bit (Modbus
,
ASCII Mode)
4: 8 data bit
,
Even parity
,
1 stop bit (Modbus
,
ASCII Mode)
5: 8 data bit
,
Odd parity
,
1 stop bit (Modbus
,
ASCII Mode)
6: 8 data bit
,
No parity
,
2 stop bit (Modbus
,
RTU Mode)
7: 8 data bit
,
Even parity
,
1 stop bit (Modbus
,
RTU Mode)
8: 8 data bit
,
Odd parity
,
1 stop bit (Modbus
,
RTU Mode)
y
:
baud rate option
0
:
4800 bps
1
:
9600 bps
2
:
19200 bps
3
:
38400 bps
4
:
57600 bps
5
:
115200 bps
Pt, Pr
S,T
0000h
~0058h
-
PC23
SIC
Communication time-out process option
Time-out inspection could be set from 1 to 60 seconds. If it is
set as 0, the inspection function is invalid.
Pt, Pr
S,T
0
~60
S
Содержание SDE Series
Страница 13: ...5 1 6 Function block diagram ...
Страница 26: ...18 3 3 3 CN1 pin name list ...
Страница 212: ...204 SDE 075A2U SDE 100A2U 750W 1KW unit mm Dimensions of the servo drive may be revised without prior notice ...
Страница 223: ...215 SME L040 SME L075 SME L100 SME L150 ...
Страница 224: ...216 SME L200 SME L300 SME M100 SME M150 Continuous running range ...
Страница 225: ...217 SME M200 SME M300 NOTE These characteristic plots above are measured in case of 3φ 200 240V power supplied ...
Страница 227: ...219 ...
Страница 231: ...223 4 Wiring example with peripheral equipment CN2 Encoder socket ...
Страница 242: ...234 12 4 Version information Version V1 01 Issue date Aug 2017 Proofreader Yaochou Shu ...