![Shihlin electric SDE Series Скачать руководство пользователя страница 150](http://html.mh-extra.com/html/shihlin-electric/sde-series/sde-series_manual_1256843150.webp)
142
(2) Vibration suppression
Vibration often occurs in a mechanism which the rigidity is poor. In such system, the settling
time of position control becomes longer. For some application, a shorter settling time is
necessary; vibration suppression function can satisfy this demand. The relevant parameters
are described below.
Name
Abbr.
Sign
Setting
range
Unit
Control
mode
Auto vibration suppression mode
AVSM
PB29
0
~1
-
Pt, Pr
Low-frequency vibration detection level
VCL
PB30
1
~800
Pulse
Pt, Pr
Vibration suppression frequency 1
VSF1
PB31
1
~3000
0.1Hz
Pt, Pr
Vibration suppression gain 1
VSG1
PB32
0
~15
-
Pt, Pr
Vibration suppression frequency 2
VSF2
PB33
1
~3000
0.1Hz
Pt, Pr
Vibration suppression gain 2
VSG2
PB34
0
~15
-
Pt, Pr
(a) Manual mode
When vibration suppression manual mode is performed, the relevant parameters PB31/PB32 and
PB33/PB34 are used to suppress the vibration. For the known vibration situation, users can set
the vibration frequency into PB31
、
PB33, then set PB32
、
PB34 as 1 to enable the suppression
function. The 0 value of PB32 and PB34 mean the vibration suppression disabled.
(b) Auto mode
When vibration suppression auto mode is performed, please set PB29=1 to enable the auto
mode. Even though the vibration frequency of mechanical system is unknown, auto mode will find
the system vibration frequency, and then record the results into PB31 and PB33, and set PB32
and PB34 as1. After the completion of auto mode, PB29 recovers 0.
After execution of auto mode, if the vibration phenomenon still exists, check PB32 and PB34
value whether they are 0. The zero value means that auto mode did not find the vibration
frequency due to a higher value setting of PB30. Users can decrease PB30 then run auto mode
again to find the vibration
frequency.
The non-zero value means auto detection fails, the result
frequency is not the exact vibration frequency, users can increase PB30 then run auto mode
again to find the vibration frequency.
Содержание SDE Series
Страница 13: ...5 1 6 Function block diagram ...
Страница 26: ...18 3 3 3 CN1 pin name list ...
Страница 212: ...204 SDE 075A2U SDE 100A2U 750W 1KW unit mm Dimensions of the servo drive may be revised without prior notice ...
Страница 223: ...215 SME L040 SME L075 SME L100 SME L150 ...
Страница 224: ...216 SME L200 SME L300 SME M100 SME M150 Continuous running range ...
Страница 225: ...217 SME M200 SME M300 NOTE These characteristic plots above are measured in case of 3φ 200 240V power supplied ...
Страница 227: ...219 ...
Страница 231: ...223 4 Wiring example with peripheral equipment CN2 Encoder socket ...
Страница 242: ...234 12 4 Version information Version V1 01 Issue date Aug 2017 Proofreader Yaochou Shu ...