86
No
Abbr.
Function description
Control
mode
Setting
range
Unit
PA32
APR
Encoder absolute position (rev) (read only)
To display the absolute encoder turn number. This parameter is
valid only when the PA28 is set as 1.
Pr, Pt
S,T
2
17
-1
~ -2
17
rev
PA33
APP
Encoder absolute position (pulse) (read only)
To display the absolute encoder pulse number. This parameter is
valid only when the PA28 is set as 1.
Pr, Pt
S,T
0
~ (2
22
-1)
pulse
PA34 ABSM
I/O communication of absolute system
0
:
Delta PLC is applied
1
:
Mitsubishi PLC is applied
Pr, Pt
S,T
0
~1
-
PA35 FNO1
Function option 1
u z y x
x
:
Torque generated and motor rotary direction
When motor run in CCW
:
0
:
the torque regenerated is in CCW
1
:
the torque regenerated is in CW
When motor run in CW
:
0
:
the torque regenerated is in CW
1
:
the torque regenerated is in CCW
y
:
rotary direction definition
0
:
When ST1 is activated, the motor start to run in CCW.
When ST2 is activated, the motor start to run in CW.
1
:
When ST1 is deactivated, the motor start to run in CCW.
When ST1 is activated, the motor start to run in CW.
The ST2 signal is invalid, the motor shaft is rotatable.
z
:
servo-lock option
0
:
servo-lock is valid, the stop position is held.
1
:
servo-lock is invalid, the stop potion is mobile.
u
:
condition of control mode switch
0
:
ZSP signal is referred when control mode is switched.
1
:
ZSP signal is not referred when control mode is switched.
Pr, Pt
S,T
0000h
~1111Fh
-
PA36 FNO2
Function option 2
(In some application, this parameter is enabled. Please do not
set it unless the customer is informed by the Shihlin engineers)
Pr, Pt
S,T
0000h
~1111Fh
-
PA37 FNO3
Function option 3
(In some application, this parameter is enabled. Please do not
set it unless the customer is informed by the Shihlin engineers)
Pr, Pt
S,T
0000h
~1111Fh
-
PA38
Reserved
Содержание SDE Series
Страница 13: ...5 1 6 Function block diagram ...
Страница 26: ...18 3 3 3 CN1 pin name list ...
Страница 212: ...204 SDE 075A2U SDE 100A2U 750W 1KW unit mm Dimensions of the servo drive may be revised without prior notice ...
Страница 223: ...215 SME L040 SME L075 SME L100 SME L150 ...
Страница 224: ...216 SME L200 SME L300 SME M100 SME M150 Continuous running range ...
Страница 225: ...217 SME M200 SME M300 NOTE These characteristic plots above are measured in case of 3φ 200 240V power supplied ...
Страница 227: ...219 ...
Страница 231: ...223 4 Wiring example with peripheral equipment CN2 Encoder socket ...
Страница 242: ...234 12 4 Version information Version V1 01 Issue date Aug 2017 Proofreader Yaochou Shu ...