![Shihlin electric SDE Series Скачать руководство пользователя страница 165](http://html.mh-extra.com/html/shihlin-electric/sde-series/sde-series_manual_1256843165.webp)
157
6.9. Other functions
Before wiring, turn off the power and wait for 10 minutes or more until the charge
LED turns off. Otherwise, an electric shock may occur.
Use the
s
pecified auxiliary equipment and options to prevent a malfunction or a
fire.
6.9.1. Selection of brake resistor
Use the
s
pecified auxiliary equipment and options to prevent a malfunction or a
fire.
As the direction of motor generated torque is opposite to the rotary direction of motor, it
becomes a power generator. The regenerative energy would be turned back to the servo drive. To
prevent from P-N voltage exceeded, a voltage stabilized protection is necessary. The IGBT switch and
brake resistors constitute this protection. Regenerative energy is consumed by the brake resistor.
There is a built-in brake resistor inside the drive (below 3.5KW). If the regenerative energy is too
large, it is not recommended to use. Instead, use an external one to avoid overheating. When using the
built-in brake resistor, make sure that the P/D terminals is short-circuit. If the external brake resistor
applied, make P/D terminals open while the external resistor is connected to the P/C terminals.
Built-in brake resistor specifications for the Shihlin servo drive are described below.
Drive(W)
Built-in brake resistor specification
Minimum permissible
(Ω)
Consumption power of
built-in resistor (W)
resistor
(Ω)
Capacity (W)
100
100
20
100
10
200
100
20
100
10
400
100
20
100
10
500
100
20
100
10
750
40
40
40
20
1000
40
40
40
20
1500
13
100
13
50
2000
13
100
13
50
3500
13
100
13
50
Note: The average regenerative power that could be consumed is at 50% rated power of the built-in
brake resistor. So are the external brake resistors.
As external brake resistor is applied, the same resistance value mentioned above is required. If
serial or parallel wiring are applied
to increase resistor‟s power, be sure that the resistance meets the
minimum permissible specification. The brake resistor with a thermal switch or a cooling fan would be
helpful to tell users that the capacity of brake resistor is insufficient or to reduce the temperature of
brake resistor. Please contact the manufacturer of brake resistor to know the detail load characteristic.
Содержание SDE Series
Страница 13: ...5 1 6 Function block diagram ...
Страница 26: ...18 3 3 3 CN1 pin name list ...
Страница 212: ...204 SDE 075A2U SDE 100A2U 750W 1KW unit mm Dimensions of the servo drive may be revised without prior notice ...
Страница 223: ...215 SME L040 SME L075 SME L100 SME L150 ...
Страница 224: ...216 SME L200 SME L300 SME M100 SME M150 Continuous running range ...
Страница 225: ...217 SME M200 SME M300 NOTE These characteristic plots above are measured in case of 3φ 200 240V power supplied ...
Страница 227: ...219 ...
Страница 231: ...223 4 Wiring example with peripheral equipment CN2 Encoder socket ...
Страница 242: ...234 12 4 Version information Version V1 01 Issue date Aug 2017 Proofreader Yaochou Shu ...