Device Settings
myUTN User Manual Windows
58
• only one power supply works
• SD card errors (read and write errors, no SD card)
Errors are displayed in codes. The meaning of the codes you will find
in chapter ’Information Shown in the Display Panel (myUTN-800
only)’
Proceed as follows:
1. Start the myUTN Control Center.
2. Select
Device – Notification
.
3. In the
Display panel
area, tick the options with the desired
message types.
4. Click
Save
to confirm.
The settings are saved.
If there is no error state, i.e. the UTN server is operational, the iden-
tifier is displayed
The optional acoustic signals ideally complement the error messages
in the display panel. For further information; see:
4.9
How to Configure Acoustic Signals (myUTN-800
only)
The myUTN-800 Dongleserver gives acoustic feedback when:
• a USB dongle is connected to the UTN server
• the UTN server restarts
• the parameters are reset
These acoustic signals cannot be turned off.
Optionally further acoustic signals can be configured for when
• only one power supply works
• an SD card error exists (read and write errors, no SD card)