5.3.3 Oil Mist lubricated bearings
The motor must be stored in horizontal position. Lubricate the bearings with ISO VG 68 mineral oil in the
amount indicated in the Table 5.2 (this is also valid for bearings with equivalent dimensions). After filling with oil,
rotate the shaft by hand, at least five revolutions)
During the storage period, remove the shaft locking device (if any) and rotate the shaft by hand every week, at
least five revolutions, stopping it at a different position from the original one. Reinstall the shaft locking device
every time the motor has to be moved. If the motor is stored for a period of over two years, the bearings must
be replaced or removed, washed according to manufacturer instructions, checked and relubricated according
to item 8.2.
5.3.4 Sleeve bearing
The motor must be stored in its original operating position and with oil in the bearings. Correct oil level must be
ensured. It should be in the middle of the sight glass. During the storage period, remove the shaft locking
device and rotate the shaft by hand every month, at least five revolutions, and at 30 rpm, thus achieving an
even oil distribution inside the bearing and maintaining the bearing in good operating conditions. Reinstall the
shaft locking device every time the motor has to be moved.
If the motor is stored for a period of over six months, the bearings must be relubricated according to the Item
8.2 before starting the operation.
If the motor is stored for a period longer than the oil change interval, or if it is not possible to rotate the motor
shaft by hand, the oil must be drained and a corrosion protection and dehumidifiers must be applied.
The oil must always be removed when the motor has to be handled. If the oil mist system is not operating after
installation, fill the bearings with oil to prevent bearing rusting. During the storage period, rotate the shaft by
hand, at least five revolutions, stopping it at a different position from the original one. Before starting the motor,
all bearing protection oil must be drained from the bearing and the oil mist system must be switched ON.
Table 5.2 -
Amount of oil per bearing
Bearing size
Amount of oil (ml)
Bearing size
Amount of oil (ml)
6201
15
6309
65
6202
15
6311
90
6203
15
6312
105
6204
25
6314
150
6205
25
6315
200
6206
35
6316
250
6207
35
6317
300
6208
40
6319
350
6209
40
6320
400
6211
45
6322
550
6212
50
6324
600
6307
45
6326
650
6308
55
6328
700
5.4. INSULATION RESISTANCE
We recommend measuring the winding insulation resistance at regular intervals to follow-up and evaluate its
electrical operating conditions. If any reduction in the insulation resistance values are recorded, the storage
conditions should be evaluated and corrected, where necessary.
5.4.1. Insulation resistance measurement
We recommend measuring the winding insulation resistance at regular intervals to follow-up and evaluate its
electrical operating conditions. If any reduction in the insulation resistance values are recorded, the storage
conditions should be evaluated and corrected, where necessary.
The insulation resistance must be measured in a safe environment.
Page 146
Содержание BN 5-12 Series
Страница 13: ...TAB 1 DEVICE DATA SHEETS ...
Страница 18: ...TAB 2 APPROVED SUBMITTAL ...
Страница 23: ...All data subject to change without notice 1 800 ASK 4WEG www weg net 14 ...
Страница 26: ...Your advantages our pumps ...
Страница 45: ...ADV 2 13E And what can we get flowing for you Your nearest contact Or visit www seepex com ...
Страница 117: ...TAB 3 INSTALLATION OPERATIONS AND MAINTENANCE ...
Страница 133: ...Page 37 ...
Страница 233: ...www weg net Manual of Electric Motors 64 ENGLISH Figure 2 1 IEC motor nameplate Page 135 ...
Страница 234: ...www weg net Manual of Electric Motors 65 ENGLISH Figure 2 2 NEMA motor nameplate Page 136 ...
Страница 306: ...TAB 4 AS BUILTS AND SUPPLEMENTAL INFORMATION ...
Страница 307: ...R Page 29 ...
Страница 308: ...R Page 30 ...