92
Assembly and Operating Instructions – Gear Units R..7, F..7, K..7, K..9, S..7, SPIROPLAN® W
6
Inspection/maintenance for the gear unit
Inspection/Maintenance
6.6.3 B: Helical, parallel-shaft helical, SPIROPLAN
®
gear units without oil level plug with cover plate
Checking the oil
level via cover
plate
For gear units without oil level bore, the oil level is checked via the cover plate opening.
Proceed as follows:
1. Observe the notes in section "Preliminary work regarding gear unit inspection/main-
tenance" (page 85).
2. For the cover plate to be on top, you have to set up the gear unit in the following
mounting position.
– R07 - R57 in M1 mounting position
– F27 in M3 mounting position
– W10 - W30 in M1 mounting position
3. Loosen the screws [1] of the cover plate [2] and remove the cover plate [2] and the
corresponding gasket [3] (see following figure).
4. Determine the vertical distance "x" between oil level and sealing surface of the gear
unit housing (see following figure).
18643211
18646283
[1]
[2]
[3]
90°
X
Page 104
Содержание BN 5-12 Series
Страница 13: ...TAB 1 DEVICE DATA SHEETS ...
Страница 18: ...TAB 2 APPROVED SUBMITTAL ...
Страница 23: ...All data subject to change without notice 1 800 ASK 4WEG www weg net 14 ...
Страница 26: ...Your advantages our pumps ...
Страница 45: ...ADV 2 13E And what can we get flowing for you Your nearest contact Or visit www seepex com ...
Страница 117: ...TAB 3 INSTALLATION OPERATIONS AND MAINTENANCE ...
Страница 133: ...Page 37 ...
Страница 233: ...www weg net Manual of Electric Motors 64 ENGLISH Figure 2 1 IEC motor nameplate Page 135 ...
Страница 234: ...www weg net Manual of Electric Motors 65 ENGLISH Figure 2 2 NEMA motor nameplate Page 136 ...
Страница 306: ...TAB 4 AS BUILTS AND SUPPLEMENTAL INFORMATION ...
Страница 307: ...R Page 29 ...
Страница 308: ...R Page 30 ...