The Multi sensors
23
6.4
Switching ON/OFF
The Multi sensors have an internal magnetic switch.
To turn a Multi sensor on, briefly hold a magnet (e.g. the foot of another Multi sensor) in
front of the sensor's I/O area
. The device turns on. The indicator light flashes
3 times.
To turn the device off, hold a magnet in front of the I/O area for approximately
2 seconds. The indicator light will flash 2 times before it goes out.
6.5
Installation
The Multi sensors should be installed directly on the pipe However, you can also attach
them to valve rods or hydrants, for example, or any other position along the pipeline that
is easily accessible. Due to their powerful magnet, the sensors can also be attached
horizontally.
There must be the best possible contact between the sensor foot or the mounted
adapter (see below) and the pipe. If need be, clean the contact point thoroughly
(preferably with a wire brush).
6.6
Angle adapter
In some situations, the Multi sensor cannot be attached directly to the desired
measurement point due to its size, e.g. in very narrow shafts or similar. In such cases, it
can be helpful to use one of the supplied angle adapters.
Thanks to its magnetic foot, the sensor is simply placed on the
adapter. Then, the magnetic adapter can be attached to the
pipe or fitting etc.
NOTE
The sensor's type plate and
I/O
area
must face
away from the angle adapter - as can be seen on
the picture.
Otherwise, the magnet of the angle adapter would
turn off the Multi sensor unintentionally.
You can screw the angle adapter firmly to the sensor.
This can be useful as the holding strength between the angle adapter and the pipe in
general is higher than the holding strength between the angle adapter and the sensor.
When collecting the sensors, it may happen that you pull the sensor from the angle
without intention. The adapter then remains on the pipe and it could be difficult to
remove it.
Magnetic connection
Screw connection