SET
DESCRIPTION
DEFAULT
SET
VALUE
Off
Disabled
Positive brake
management
Positive electric-brake (The relay FV2 will be ON only
with stopped gate)
Negative brake
management
Negative electric-brake (The relay FV2 will be ON only
with automation in cycle and 1 second before starting
movement)
Negative brake
management and
Photocell
Negative electric-brake (The relay FV2 will be ON only
during gate cycle and 1 second before start , except in
case of photocell intervention)
Fan
The relay on FV MODULE will activate for the whole
cycle duration plus 2 further minutes
136
EFO
0% 100%
The EFO function generates a closing with a higher
speed than the set percentage. It works only with
bollard through a command on the PEDESTRIAN START
input
50%
137
COMIS
0 350 mA
It shows the absorption of the accessories connected
on input 20
- - - -
138
COMIS THRESHOLD
Off 350mA
Allows to set a maximum absorption threshold over
which an error message appears (error message
appears also when over 350 mA)
Off
140
THRESHOLD A
OPENING 1
1 10 Ampere
Adjusts the amperometric intervention threshold of
motor 1 in opening (over the set threshold the motor
will detect an obstacle)
It
depends
on motor
141
THRESHOLD A
CLOSING 1
1 10 Ampere
Adjusts the amperometric intervention threshold of
motor 1 in closing (over the set threshold the motor
will detect an obstacle)
It
depends
on motor
142
THRESHOLD A
OPENING 2
1 10 Ampere
Adjusts the amperometric intervention threshold of
motor 2 in opening (over the set threshold the motor
will detect an obstacle)
It
depends
on motor
143
THRESHOLD A
CLOSING 2
1 10 Ampere
Adjusts the amperometric intervention threshold of
motor 2 in closing (over the set threshold the motor
will detect an obstacle)
It
depends
on motor
144
THRESHOLD A
OPENING SLOWDOWN 1
1 10 Ampere
Adjusts the amperometric intervention threshold of
motor 1 in slowdown during opening
It
depends
on motor
145
THRESHOLD A
CLOSING SLOWDOWN 1
1 10 Ampere
Adjusts the amperometric intervention threshold of
motor 1 in slowdown during closing
It
depends
on motor
146
THRESHOLD A
OPENING SLOWDOWN 2
1 10 Ampere
Adjusts the amperometric intervention threshold of
motor 2 in slowdown during opening
It
depends
on motor
147
THRESHOLD A
CLOSING SLOWDOWN 2
1 10 Ampere
Adjusts the amperometric intervention threshold of
motor 2 in slowdown during closing
It
depends
on motor
190
BASIC MENU
Press OK to exit the special menu.
The special menu switches off automatically after 20 minutes
Note 1:
The * indicates that the default value or the menu may change depending on the selected motor type
Note 2:
After initialization the parameters "motor type" and "limit switch type" remain on the value chosen in the setup program
Note 3:
Display writing speed set on 30% keeps writing slow; Display writing speed set on 100% keeps writing fast
Please note that speed does not change on JOLLY 3 display
135
RELAY FV 2
(Relay on the FV
MODULE 2)
It depends
on motor
MENU SP
35