COM
LSO1
LSC1
24V
21 22
LIMIT SWITCH CoNNECTIoNS
LIMIT SWITCH 14 15 16 17 18
Does not need a jumper when not connected.
For the limit switch function, limit switches must be installed, both in opening and closing. In the
case of single-leaf connect motor 1 (it is not necessary to bridge the limit switches of motor 2).
Anti-intrusion function can be activated. This function needs at least one limit switch, which pushes
the motor in closing direction once it’s released.
ELECTrIC LoCK oUTpUT 21 22
A 12V=15W max electric lock can be connected
The electric lock can be deactivated when not used for energy saving on the control unit.
The electric lock release can be timed from 0 to 5 seconds
The electric lock can be set: only before opening, only before closing or in both directions.
MAGLoCK CoNNECTIoNS
NOTA:
set the negative electric brake function in menu 132.
For the correct functioning of the limit switches there must be a correspondence between the
direction of movement of the motors and the respective
engaged limit switches.
Quick connector
sliding limit switch
CLS
Note:
on some motors, the opening and closing limit-switch inputs 2 are used as a slow-down limit switch.
See BIG FAST Joint.
ENGLISH
19