MENU SEA SET
10K PHOTOCELL (SINGLE OR DOUBLE) 7 and 11 - 8 and 11
On the clamps 7 and 11 - 8 and 11 of the CN1 it is also possible to connect a 10K Photocell.
On menu 121 type photo 1 and on the menu 122 type photo 2, it will work according to the settings
given from menu 97-PHOTO 1 and 98 Photo 2.
Note1: Using the 10K Photocell, further protection will be provided
also
in the event of a short-circuit
on the cables.
Setting 10 K Photocell
121 PHOTO 1
TYPE
SAFETY EDGE 9 and 11 - 10 and 11
It is possible to connect a safety edge between the contacts 9 and 11 of CN1 (or two edges, with the
second one connected between the contacts 10 and 11) . When pressed, the Safety Edge opens
the contact causing a partial inversion of the movement both in opening and in closing. The Safety
Edge input can be set «only in closing», «only in opening» or both.
Note1: Through the on-board display or the JOLLY 3 programmer it is possible to activate the
balanced edge 8K2, in this case the edge contact is controlled by a special resistance value
revealing the eventual involuntary short- circuit of the device. In the case of imbalance of the device
a special alarm will be shown on the on-board display or on the JOLLY programmer.
It is also possible to set two 8K2
Safety Edges
on each single input
Safety Edge
.
Note2: Self-test can be made also on a powered radio Edge (See Auto-test Menu)
Latch open / latch close f
unction
Inputs 10 and 11 can be set accordingly as latch open and latch close - see menu 118.
UP
OK
OK
MENU
MENU
SEA
SEA
OFF
Photo 10K
SET
SET
ENGLISH
16