SET
DESCRIPTION
DEFAULT
SET
VALUE
Always
AUX output always power supplied
In cycle
AUX output active only during cycle
Opening
AUX output power supplied only during opening
Closing
AUX output power supplied only during closing
In pause
AUX out put power supplied only during pause
Autotest
Security test
In cycle and photo-test
AUX active only during cycle with photo-test function
In cycle and pause
AUX power supplied during cycle and during pause
Courtesy light
It will work as per Menu-88 settings
Barrier and Bollard
LED lights
the 24Vaux output will pilot the lights on the automa-
tion so that, when it is closed the light is switched-on,
when open the light is switched-off and when the
automation is moving the light blinks
Open gate warning Light
1 flash per second in opening
2 flashes per second in closing
Steady lit in Stop or Open
Photo 1
Self-test active only on photo 1
Photo 2
Self-test active only on photo 2
Photo 1 and 2
Self-test active on photo 1 and 2
Off
Disabled
Edge 1
Test enabled on edge 1
Edge 2
Test enabled on edge 2
Edges 1 and 2
Test enabled on edges 1 and 2
Off
Disabled
Closing
If the photocell is occupied during closing, it reverses
the movement; it prevents the reclosing during pause
Opening and closing
If occupied, the photocell stops the movement as long
as it is busy
;
when released, the opening movement
continues
Stop
If the photocell is activated before the Start input, the
Start will be ignored. If it is activated after the Start
input, the photocell will be ignored. If it is activated
during closing, the gate will reopen
Stop and close
In closing, the photocell stops the movement until it is
occupied; when released the closing movement
continues
Close
The photocell stops the gate until it is occupied in both
opening and closing; when released, it gives a closing
command (it closes one sec. after its release)
Closing
Pause reload
If occupied during the pause, the photocell recharges
the same pause time set. In closing it reverses the
movement
Opening and Closing
Pause reload
If occupied during the pause, the photocell recharges
the same pause time set. In closing it reverses the
movement; in opening it stops the automation and
when the photocell is released the opening continues
Shadow loop
If occupied, with open gate, the shadow loop prevents
reclosing. It is switched off during closing
Delete pause time
If occupied during opening, pause or closing, the gate
reopens completely and closes without observing the
pause time
Shadow loop PR
(pause reloading)
If the shadow loop is temporarily released, the pause
time is reloaded before closing
97
PHOTOCELL 1
Closing
95
PHOTO-TEST
Off
96
SECURITY EDGE
SELF-TEST
Off
94
24V AUX
(Max. 500 mA)
Always
MENU SP