SET
DESCRIPTION
DEFAULT
SET
VALUE
17
OPENING SPEED 1
30 100
Speed in opening Motor 1
80
18
CLOSING SPEED 1
30 100
Speed in closing Motor 1
80
19
OPENING SPEED 2
30 100
Speed in opening Motor 2
80
20
CLOSING SPEED 2
30 100
Speed in closing Motor 2
80
21
SLOWDOWN SPEED IN
OPENING 1
From 10% to 60%
of the maxinmum speed
Slow-down speed in opening Motor 1
30
22
SLOWDOWN SPEED IN
CLOSING 1
From 10% to 60%
of the maxinmum speed
Slow-down speed in closing Motor 1
30
23
SLOWDOWN SPEED IN
OPENING 2
From 10% to 60%
of the maxinmum speed
Slow-down speed in opening Motor 2
30
24
SLOWDOWN SPEED IN
CLOSING 2
From 10% to 60%
of the maxinmum speed
Slow-down speed in closing Motor 2
30
25
LEARNING SPEED
20% 100 %
Adjusts the time self-learning speed. This parame-
ter can change according to the motor type set
50
26
LEAF DELAY IN OPENING
Off 6
Setting from OFF to 6 seconds
1,5
27
LEAF DELAY IN CLOSING
Off 20
Setting from OFF to 20 seconds
2,5 *
28
OPENING TORQ 1
50% 100 %
Opening torque Motor 1: by increasing the torque,
more strenght will be required to execute the inversion
in case of obstacle
100%
29
CLOSING TORQ 1
50% 100 %
Closing torque Motor 1: by increasing the torque, more
strenght will be required to execute the inversion in
case of obstacle
100%
30
OPENING TORQ 2
50% 100 %
Opening torque Motor 2: By increasing the torque,
more strenght will be required to execute the inversion
in case of obstacle
100%
31
CLOSING TORQ 2
50% 100 %
Closing torque Motor 2: By increasing the torque, more
strenght will be required to execute the inversion in
case of obstacle
100%
32
ENCODER
On
In ON enables the Encoder, in OFF it's disabled
Off
47
ENCODER PAR. 1
xxx.
48
ENCODER TOT. 1
xxx.
49
ENCODER PAR. 1
xxx.
50
ENCODER TOT. 2
xxx.
32
ENCODER
Potentiometer
Enables the reading of the potentiometer
Off
51
I.PAR.M1
- - - - - - - -
52
I.AP.M1
From the value learnt
to ± 100 pulses
53
I.CH.M1
From the value learnt
to ± 100 pulses
54
I.PAR.M2
- - - - - - - -
55
I.AP.M2
From the value learnt
to ± 100 pulses
56
I.CH.M2
From the value learnt
to ± 100 pulses
Reports the current position of the potentiometer on the leaf of motor
1. This parameter is useful for seeing if the potentiometer is read
correctly
Reports the impulses stored by the control unit when the leaf of Motor
1 is fully open
Reports the impulses stored by the control unit when the leaf of Motor
1 is fully close
Reports the current position of the potentiometer on the leaf of Motor
2. This parameter is useful for seeing if the potentiometer is read
correctly
Reports the impulses stored by the control unit when the leaf of Motor
2 is fully open
Reports the impulses stored by the control unit when the leaf of Motor
2 is fully close
SPECIAL MENU
PRESS AT THE SAME TIME FOR 5 SECONDS TO ENTER OR TO EXIT THE SPECIAL MENU
SPECIAL MENU FUNCTIONS TABLE UNIGATE FV
For entering into the special menu move on one of the menu and press the UP and DOWN buttons at the same time for 5 seconds For
exiting the special menu press END or move on one of the menu and press the UP and DOWN at the same time for 5 seconds
MENU SP
Impulses read by Encoder during operation (Motor1)
Impulses stored during programming (Motor 1)
Impulses read by Encoder during operation (Motor2)
Impulses stored during programming (Motor 2)
UP
DOWN
25