poSITIoN GATE CoNNECTIoNS
The position gate allows to know the
exact position of the gate and to have
the reverse on the obstacle. The position
gate is applicable on the hydraulic
motors Half Tank and Mini Tank new
series, in combination with the LE card.
Note:
for distances of more than 2 meters, it is recommended to connect a shielded cable with a sheath
connected to COM 25
If the reading of the potentiometer is reversed compared to the movement of the motor, on the
display will appear the alarm “Potentiometer direction” and you will have to reverse the brown wire
with the green one and repeat programming.
AMpEroMETrIC DEVICE For ELECTroMECHANICAL opErATorS
(active on Surf motor IV)
This control unit comes with an obstacle detection system working only on electromechanical
operators allowing to have the reversing on obstacles and the automatic detection of the stops.
Sensitivity adjustable from OFF to 99% in the special menu. The more the percentage is high the
more the obstacle detection will be difficult. On hydraulic unit this parameter will be always OFF.
Adjustable sensitivity intervention threshold. See menus 33 to 45.
The sensitivity on the obstacle is adjustable from 0 - 99%. The higher the percentage, the more
difficult it will be to detect the obstacle.
ENCoDEr CoNNECTIoNS
The encoder allows to know
the position of the gate and
to have the inversion on the
obstacle. To use the encoder
it is necessary to activate it in
the appropriate “32 encoder
on” menu. The sensitivity on
the obstacle is adjustable from
0 - 99%.
The higher the percentage, the
more difficult it will be to detect
the obstacle
To use the position gate, activate it in the
32 encoder menu: potentiometer
ENGLISH
20