pHoToCELL AND ANTENNA CoNNECTIoNS
A) 24V DC 11 and 12
PHOTOCELL 1 AND PHOTOCELL 2 (LOOP1 - LOOP2)
11 and 12 aux ~ (Accessories) 1A max COM = 0V
7 PH1 = Photocell contact 1
8 PH2 = Photocell contact 2
Default settings:
PHOTO 1 = “Close” - PHOTO 2 = “Open”
Photocell 2 can also be set as TIMER (see below TIMER function). For photocell options, see menu
97 and 98.
TIMER: holding PH2 pressed, the gate opens and remains open, while, when released, the gate
repeats the selected pause time and starts closing. If a safety device is activated, the Timer resets
automatically after 6 sec.
AUTOTEST function: make sure that the photocells are fully functional before any movement. If the
test fails, it will be indicated on the display.
To activate the AUTOTEST:
1) Connect the TX photocell power supply to the aux 12 inputs
2) Enter the 95-FOTOTEST menu and select on which accessory (Photocell 1 or Photocell 2 or
both) to activate this mode.
If you want to monitor the absorption of accessories, connect them to the inputs 20 of CN2 (
COMIS)
max 350mA
B) CoNFIGUrATIoN 24V DC AUX CN1 12 CoNFIGUrATIoN
On the 24V AUX you can select when and how to operate the connected auxiliary accessory.
See menu 94-24V AUX.
The 94-24V AUX menu options are:
(See special menu)
• Always
• In cycle
• Opening
• Closing
• In pause
• Self-test
• In cycle and phototest
• In cycle and pause
• Indicator light gate open