SET
DESCRIPTION
DEFAULT
SET
VALUE
Closing
If the photocell is occupied during closing, it reverses
the movement; it prevents the reclosing during pause
Opening and closing
If occupied, the photocell stops the movement as long
as it is busy
;
when released, the opening movement
continues
Stop
If the photocell is activated before the Start input, the
Start will be ignored. If it is activated after the Start
input, the photocell will be ignored. If it is activated
during closing, the gate will reopen
Stop and close
In closing, the photocell stops the movement until it is
occupied; when released the closing movement
continues
Close
The photocell stops the gate until it is occupied in both
opening and closing; when released, it gives a closing
command (it closes one sec. after its release)
Opening
Pause reload
If occupied during the pause, the photocell recharges
the same pause time set. In opening, the gate stops
and when released the movement continues
Opening and Closing
Pause reload
If occupied during the pause, the photocell recharges
the same pause time set. In closing it reverses the
movement; in opening it stops the automation and
when the photocell is released the opening continues
Shadow loop
If occupied, with open gate, the shadow loop prevents
reclosing. It is switched off during closing
Delete pause time
If occupied during opening, pause or closing, the gate
reopens completely and closes without observing the
pause time
Shadow loop PR
(pause reloading)
If the shadow loop is temporarily released, the pause
time is reloaded before closing
Stop and open
If the photocell is activated during opening, the gate
will stop and will continue opening movement only
when the photocell is released. The photocell is
ignored during closing
99
PHOTO OFF IN CLOSING
0% 50%
In closing, it excludes the photocell reading for the
space percentage set
0%
Normal
Normal N.C. contact
8K2
Edge is active and protected by a 8K2 resistor
8K2 Double
Allows to connect two 8K2 protected edges
Normal
Normal N.C. contact
8K2
Edge is active and protected by a 8K2 resistor
8K2 Double
Allows to connect two 8K2 protected edges
Opening and closing
Active in opening and closing
Only opening
Active only in opening
Only closing
Active only in closing
Opening and closing
Active in opening and closing
Only opening
Active only in opening
Only closing
Active only in closing
102
SECURITY EDGE 1
DIRECTION
Opening
and
Closing
103
SECURITY EDGE 2
DIRECTION
Opening
and
Closing
101
SECURITY EDGE 2
Normal
98
PHOTOCELL 2
Opening
and
closing
MENU SP
100
SECURITY EDGE 1
Normal
30