SET
DESCRIPTION
DEFAULT
SET
VALUE
Normal
Standard photocell without 10K control
Photo 1 10K
Photocell with 10K control
Normal
Standard photocell without 10K control
Photo 2 10K
Photocell with 10K control
123
DATE AND TIME
Mon - Sun
dd/mm/yyyy
Time
Allows to set the day, date and time for the manage-
ment of the programmed openings. (Only if the buffer
battery is present and is charge)
- - - -
124
CLOCK 1
Opening time
Closing time
Days
End
Allows the setting of a first time band in which keeping
the gate open. It is possible to set, in order, opening
time, closing time and the days on which you want to
open and keep the gate open
- - - -
125
CLOCK 2
Opening time
Closing time
Days
End
Allows the setting of a first time band in which keeping
the gate open. It is possible to set, in order, opening
time, closing time and the days on which you want to
open and keep the gate open
- - - -
126
CLOCK 3
Opening time
Closing time
Days
End
Allows the setting of a third time band in which
keeping the gate open. It is possible to set, in order,
opening time, closing time and the days on which you
want to open and keep the gate open
- - - -
127
CLOCK 4
Opening time
Closing time
Days
End
Allows the setting of a fourth time band in which
keeping the gate open. It is possible to set, in order,
opening time, closing time and the days on which you
want to open and keep the gate open
- - - -
Off
Disabled
Emergency open
Allows the connection of an opening button that
allows the automation operating in "Dead Man" logic.
The button will only work in case of safety devices
failure or in case of stuck Start button
Open
Allows the connection of an opening button that
allows the automation operating in "Dead Man" logic.
The button will only work when the gate is closed or
after a Stop command
Thermometer
Allows the connection of a temperature probe to see
an external temperature which will be shown on the
control unit display by accesing the 109-menu
(Example: probe for detection of hydraulic motor oil
temperature)
Off
Disabled
Emergency close
Allows the connection of a closing button that allows
the automation operating in "Dead Man" logic. The
button will only work in case of safety devices failure
or in case of stuck Start button
Close
Allows the connection of a closing button that allows
the automation operating in "Dead Man" logic. The
button will only work when the gate is closed or after
a Stop command
Thermometer
Allows the connection of a temperature probe to see
an external temperature which will be shown on the
control unit display by accesing the 109-menu
(Example: probe for detection of hydraulic motor oil
temperature)
121
PHOTO 1 TYPE
Normal
122
PHOTO 2 TYPE
Normal
130
GP1
Off
MENU SP
131
GP2
Off
32