SET
DESCRIPTION
DEFAULT
SET
VALUE
Off
Disabled
Start 3s
The relay 2 is activated for 3 seconds at every Start
input or every opening command
Traffic light 1
The relay 2 will manage a traffic light with green light
on only with open gate
Traffic light in entrance
At a Start command the traffic light in entrance turns
green and the access priority is acquired while the
traffic light in exit turns red. (with TRAFFIC LIGHT BY
RESERVATION menu ON )
Traffic light in exit
At a Start command the traffic light in exit turns green
and the priority is acquired while the traffic light in
entrance
turns
red.
(with
TRAFFIC
LIGHT
BY
RESERVATION menu ON )
Lock copy
The relay 2 will be On for the time set on LOCK menu
Flashing light copy
The relay 2 repeats the flashing-light functions
Courtesy light copy
The relay 2 will be On for the time set on COURTESY
LIGHT menu
Opening 1 limit-switch
The relay 2 will be On if the motor 1 opening limit-
switch is activated or if motor 1 is in "Open" status
Closing 1 limit-switch
The relay 2 will be On if the motor 1closing limit-switch
is activated or if Motor 1 is in "Closed" status
Opening 2 limit-switch
The relay 2 will be On if the Motor 2 opening limit-
switch is activated or if Motor 2 is in "Open" status
Closing 2 limit-switch
The relay 2 will be On if the motor 2closing limit-switch
is activated or if motor 2 is in "Closed" status
Tx Relay
It is possible to activate the relay 2 for 3 seconds by
giving an impulse from the remote control
Negative brake and
Photocell 2 management
The negative electric-brake is not active on the inter-
vention of the photocell
Negative brake 2
management
Negative electric-brake (in On with the gate in cycle
and 1 second before the Start input)
Positive brake 2
management
Positive electric-brake (in On with stationary gate)
Opening electric-valve
The relay 2 is active during opening
Closing electric-valve
The relay 2 is active during closing
Off
Disabled
Positive brake
management
Positive electric-brake (The relay FV1 will be ON only
with stopped gate)
Negative brake
management
Negative electric-brake (The relay FV1 will be ON only
during gate cycle and 1 second before start)
Negative brake
management and
Photocell
Negative electric-brake (The relay FV1 will be ON only
with during gate cycle and 1 second before start,
except in case of photocell intervention)
Fan
The relay on FV MODULE will activate for the whole
cycle duration plus 2 further minutes
MENU SP
133
RELAY 2
Off
134
RELAY FV 1
(Relay on the FV
MODULE 1)
It depends
on motor
34