pEDESTrIAN STArT - STop - STArT - CoNNECTIoNS
pEDESTrIAN STArT (N.o.) 4
Function 1 (STANDARD): partial opening space adjustable from 5 to 100 (90-OPENING menu)
Function 2 (TIMER): by holding the pedestrian (4) the gate opens and remains open. Releasing it
the gate repeats the selected pause
and starts closing. In the case of a safety device activation the
timer will automatically reset after 6 sec.
Function 3 (2 BUTTONS): in 2 buttons logic press the pedestrian Start (4) to close the gate.
Function 4 (DEADMAN): in deadman logic this button executes the re-closing if you keep it pressed.
STop (N.C.) 5
When pressing this button the motor immediately stops in any condition/position. To re-start the
movement give a start command. After a stop the motor always re-starts in closing.
STArT (N.o.) 3
Function 1 (STANDARD): an impulse given to this contact opens and closes the automation
depending on the selected logic.
Function 2 (TIMER): holding START starts the TIMER function, releasing the start, the operator
repeats the pause and then re closes. To connect other devices (e.g. the loop) refer to the related
instructions leaflets (ie. loop detectors and proximity Switches). In the case of activation of a safety
device the timer will automatically reset after 6 seconds.
Function 3 (2 BUTTONS): in 2 buttons logic this button performs the opening.
Function 4 (DEADMAN): in deadman logic keep pressed the Start for the opening of the automation.
ENGLISH
17