SET
DESCRIPTION
DEFAULT
SET
VALUE
Off
Disabled
Start 3s
Activates the relay 1 for 3 seconds at every Start or
reopening command
Traffic light 1
The relay 1 will manage a traffic light with green light
switched on only when the gate is open
Traffic light in entrance
At a Start command, the traffic light in entrance turns
green and the access priority is acquired while the
traffic light in exit turns red. (with TRAFFIC LIGHT BY
RESERVATION menu ON)
Traffic light in exit
At a Start command the traffic light in exit turns green
and the access priority is acquired while the traffic light
in
entrance
turns
red.
(
TRAFFIC
LIGHT
BY
RESERVATION menu ON)
Lock copy
The relay 1 will be On for the time set on LOCK menu
Flashing light copy
Relay 1 repeats the flashing-light functions
Courtesy light copy
The relay 1 will be On for the time set on COURTESY
LIGHT menu
Opening 1 limit-switch
The relay 1 will be On if the motor 1 opening limit-
switch is activated or if motor 1 is in "Open" status
Closing 1 limit-switch
The relay 1 will be On if the motor 1closing limit-switch
is activated or if motor 1 is in "Close" status
Opening 2 limit-switch
The relay 1 will be On if the motor 2 opening limit-
switch is activated or if motor 2 is in "Open" status
Closing 2 limit-switch
The relay 1 will be On if the motor 2closing limit-switch
is activated or if motor 2 is in "Closed" status
Tx Relay
It is possible to activate the relay 1 for 3 seconds by
giving an impulse from the remote control
Negative brake and
Photocell 1 management
The negative electric-brake is not active on the inter-
vention of the photocell
Negative brake 1
management
Negative electric-brake (in On with the gate in cycle
and 1 second before the Start input)
Positive brake 1
management
Positive electric-brake (in On with stationary gate)
Opening electric-valve
The relay 1 is active during opening
Closing electric-valve
The relay 1 is active during closing
132
RELAY 1
Off
MENU SP