SET
DESCRIPTION
DEFAULT
SET
VALUE
Italiano
Italian
English
English
Français
French
Español
Spanish
Dutch
Dutch
Start
Start
Partial opening
Partial opening
External module
External module
Stop
Stop
Relay 1
To Activate Relay 1 for 3 seconds. This function requires
menu "Relay 1" set on "TX Relay"
Relay 2
To Activate Relay 2 for 3 seconds. This function requires
menu "Relay 2" set on "TX Relay"
Bistable Stop
Pressed once, it stops the gate. Pressed twice, it reactivates
the START input
Latch opening
1 impulse opens and keep open.
A second impulse restore the movement
Latch closing
1 impulse closes and keep closed.
A second impulse restore the movement
Unloch
Storing of a command to unlock the electric brake
Delete a transmitter
Deletes single transmitter
Move to EEP
Transfers the Tx stored on the control unit to an external
EEPROM (MEM), if connected
Clear memory
Deletes transmitter memory
End
“Transmitters” menu output
Hydraulic *
230V Hydraulic operators -
Series I (INVERTER)
Barrier *
230V Barrier -
Series I (INVERTER)
Lepus Fast *
Lepus FAST
BIG Fast **
BIG Super Fast **
BIG 2000 Fast - BIG Super Fast sliding operators
Series I BIG (INVERTER BIG)
BIG **
BIG 4000 sliding -
Series I BIG (INVERTER BIG)
Bollards **
Bollards -
Series I BIG (INVERTER BIG)
Surf *
Surf operator
Lepus Reversible *
Lepus Reversible
Joint BF *
4 limit-switches hydraulic operator -
Series I (INVERTER)
Off
Disabled
On
In ON activates single leaf mode (Motor1)
On
In ON reverses opening with closing and/or vice-versa (both
limit-swiches are reversed)
Off
Off
Automatic
Automatic
Open-stop-close-stop-open
Step by step type 1
Open-stop-close-open
Step by step type 2
2 button
Two buttons
Safety
Safety
Dead man
Dead man
Off
OFF (semi-automatic logics)
1 240
Setting from 1 second to 4 minutes
Off
The Start is not acceped during pause
On
The Start is acceped during pause
9
PROGRAMMING
Off On
Times learning start
Off
10
TEST START
Off On
Start command
Off
14
RESET
15
END
16
SPECIAL MENU
* Operators to be managed through UNIGATE 1I or UNIGATE 2I ** Operators to be managed through UNIGATE 1I BIG or UNIGATE 2I BIG
8
START IN PAUSE
Off
6
LOGIC
Automatic
7
PAUSE TIME
Off
UNIGATE FV MENU FUNCTIONS TABLE
MENU
1
LANGUAGE
English
4
ONE SINGLE LEAF
*
On
5
REVERSE MOTOR
Off
2
TRANSMITTERS
Start
Partial
Opening
3
MOTOR
Hydraulic
A count-down of 5 seconds will start by holding the UP button; at its end "INIT" will appear on the display as
confirmation of the control board reset
Press OK to return to the display of the firmware version and to the one of inputs state
Press OK to enter the special menu
24