![SCHUNK SRM 10 Скачать руководство пользователя страница 89](http://html.mh-extra.com/html/schunk/srm-10/srm-10_assembly-and-operating-manual_1216055089.webp)
Assembly and settings, size 16 - 40
7.4.3 Mounting programmable magnetic switch MMS 22-PI1
CAUTION
Risk of damage to the sensor during assembly!
•
Observe the maximal tightening torque.
The sensors can be mounted via four grooves in the housing of the
product.
1. Connect sensor and secure cable, see the Sensor Assembly and
Operating Manual.
2. Apply air pressure to connection "A" (4).
✓
Pinion (2) swivels towards the end position.
3. Hold teaching tool to the sensor (1) until the sensor flashes.
4. Insert or screw the sensor (1) into the groove (5), until the
sensor flashes rapidly.
5. Tighten set screw (8).
✓
Tightening torque: 10 Ncm
6. Bleed connection "A" (4).
7. Actuate connection "B" (3).
✓
Pinion (2) swivels into the other end position.
8. Repeat steps for the second sensor.
9. Check the switching position and test its function.
89
12.00 | SRM | Assembly and Operating Manual | en | 1346850