Mounting and adjustments, size 10 - 14
46
12.00 | SRM | Assembly and Operating Manual | en | 1346850
Absorber variant -X
Connections on the MDF for variant with external stop (Variant -X)
1
Fluid connection - Input
2
Fluid connection - Output
Hose-free direct connection
2.1
Connection "1"
2.2
Connection "2"
2.3
Connection "3"
2.4
Connection "4"
2.5
Reference point for connections - marking on the pinion
Hose-free direct connection
3
Product
4 *
Flat gasket
5
Attachment
* Contained in accessory pack.
Note: At the factory all connections have been closed with screw
plugs. Remove screw plugs only if connections are needed.
Dimensions
Item Designation
SRM
10
12
14
1
Fluid connection
Input
M 3
M 3
M 3
Maximum outer diameter
Ø 8.5 Ø 8.5 Ø 8.5
5
Surface - contact surface seal
Rz 4.5 Rz 4.5 Rz 4.5
Maximum diameter of mounting hole
Ø 1.5 Ø 2
Ø 2