![SCHUNK SRM 10 Скачать руководство пользователя страница 67](http://html.mh-extra.com/html/schunk/srm-10/srm-10_assembly-and-operating-manual_1216055067.webp)
Assembly and settings, size 16 - 40
7.2.2 Pneumatic connection
7.2.2.1 Base unit
Compressed air connection, base unit
Designation
Function
Main air connections
A *
Exhaust air throttle valve
Swiveling 0° - 90° or 0° - 180°
B *
Exhaust air throttle valve
Swiveling 90° - 0° or 180° - 0°
Hose-free direct connection
a
Swiveling 0° - 90° or 0° - 180°
b
Swiveling 90° - 0° or 180° - 0°
1
Attachment
2 *
O-ring
3
Product
4 *
Exhaust air throttle valve
5 *
Fixed throttle
* Contained in accessory pack.
Dimensions
Item Designation
SRM
16
20
25
32
40
A, B Main connections
M 5
M 5
M 5
G 1/8" G 1/8"
a, b O-ring [mm] -
(Hose-free direct
connection)
Ø4 x
1.5
Ø6 x
1.5
Ø6 x
1.5
Ø6 x
1.5
Ø6 x
1.5
67