7. Fault Finding
LEVELSET O/P 12
Meaning: Levelset Output Will Not Work. In the example shown, output 12 is
a levelset output, but its assignment means that it will never work.
Action:
Check Menu 51.
ARMING STN 2
Meaning: Too Many Levels Assigned to Arming Station. In the example
shown Keypad 2 is an arming station. You can only assign one
Level to an arming station.
Action:
Check Menu 47.
NON KEY Z IN LA
Meaning: No Keyswitch Zone In Level. In the example shown Level A has
been assigned a keyswitch zone which is not a keyswitch zone
type.
Action:
Check Menu 41 or 32.
KEYSWITCH ZONES
Meaning: Keyswitch Zone Assigned to Different Levels. In the example
shown a keyswitch zone has been assigned to more than one
Level in the same Partition.
Action:
Check Menu 41.