36
496234
4. Programming
Example 1: Full Set and Three Part Sets
This subsection shows how to program the 808 as an alarm system with a
full set Level, and three part set Levels. The diagram below shows an
example site where this type of system may be used.
Dining
Room
Kitchen
Living Room
Hall
Ground Floor
Office
Garage
Bathroom
Bedroom 1
Bedroom 2
Bedroom 3
Bedroom 4
Area 3
First Floor
Area 1
Area 4
Area 2
Z1
Z2
Z4
Z5
Z7
Z10
Z8
Z6
Z3
Arming Station
Figure 20. Site Plan for Example 1
The end station and main keypad are fitted under the stairs on the ground
floor (Area 1). The main keypad is programmed as keypad number 1.
Bedroom 1 is fitted with a second 927 keypad, to which is attached a PIR on
the landing. The bedroom keypad is programmed as keypad number 2. The
system assigns the attached landing PIR to zone 10 (see "3 Installation -
Using a 927 FSL Zone").
Figures 21 and 22 show the sequence of Menus to use to program the
system for the example.
Use Menu 31 to give each zone an eight character name. If a detector
activates an alarm, the system reports the zone name on the display when a