496234
25
3. Installation
Initial Power Up
Power-Up With Mains
Note: Depending on the status of the system when it is powered-up, e.g., open
tampers etc., some screens may differ from those shown below.
1.
Apply battery power first, then connect the mains.
The keypad display shows the Software version number followed by
the date.
After 3 seconds, the display shows the time:
16:07
2.
Key in the factory default user code (1234) and press Enter.
The display shows one of the following messages depending on how
the system is currently set up:
SYS DIS RST REQ
3.
Key-in the factory default installer code zero (0) + 7890,
then press Menu.
The display shows:
MENU NO OR LEVEL
4.
Press 0.
The display shows:
0:INST PROG
5.
Press Enter.
The display prompts you to remove the end station lid:
REMOVE LID
6.
If the end station Tamper Switch is already open, close and open it
again.
You have now reached the Installer programming
mode. The display shows:
00-PROG SYSTEM
808 sect 3 installation.p65
9/8/98, 10:27 AM
25
Содержание 808
Страница 1: ...HARDWIRED CONTROL PANEL INSTALLATION AND PROGRAMMING GUIDE Scantronic Leading the way in security 808 ...
Страница 8: ...6 496234 Contents ...
Страница 28: ...26 496234 3 Installation ...
Страница 30: ...9 8 98 10 57 AM ...