2. Technical Specification
be thicker. The criterion is that at the last keypad the voltage between 0V
and 12V wires must be no less than 10.5V.
Zone Wiring
The recommended maximum distance for FSL zones using standard alarm
cable is 200m - 300m.
Software Limits
The 808 can support:
•
One to four Levels.
•
Four Areas in total.
•
Eight zones provided by the end station PCB plus three zones
provided by the keypad.
•
Three outputs provided by the end station PCB.
•
Four Flexi-Zones per Level.
•
8 User codes, including one Supervisor.
See the Examples in "5. Programming" for more details.
Compatible Equipment
927
8 character LCD keypad new style case
929
8 character LCD keypad
947
Portable printer ( Battery powered ) and power supply unit
949
Wall Mounted Printer Bracket
951
Printer lead
9040
16 Ohm internal sounder
2081/2
Loudspeaker /Microphones for use with 8450
5148
1 Amp BABT approved Remote Power supply
9056
Plug-on Digital Communicator
Plug-on RedCare STU (manufactured by others)
9076-01/2
Signalling Interfaces