3. Installation
Bell
Siren
TR
0V
12V
Bell
Strobe
End Station
Bell
-ve Tamper Return
-ve Hold Off
+ve Hold Off
-ve Apply trig
-ve Remove trig
-ve Strobe O/P
Typical SAB
Strobe
9040 16 Ohm LS
(2 Max.)
See Note 1
See Note 2
Notes:
1. If SCB trigger programmed.
2. Alternative strobe trigger if
ABI requirements apply.
Figure 14. External/Internal Sounder Connection
Using Programmable Outputs
The Bell and OP2 outputs on the Main Connector provide Negative Applied
or Negative Removed control signals. OP3 provides Positive Applied or
Positive Removed control signals. Note that when using Menu 51 the Bell
output (OP1) is fixed as a Bell output type.
Wiring Keyswitches
Figures 15 to 17 show how to connect two- or three position keyswitches.
Each keyswitch occupies one 2-wire FSL zone connection or one 4-wire CC
connection. This can be any of zones 1 to 8 on the end station Main Con-
nector.
To ensure that the keyswitches work correctly use Menu 32 to program a
keyswitch zone and Menu 41 to allocate the keyswitch zone to a specific
Level (see "4. Programming - Example 3 Keyswitches").