42
496234
4. Programming
Example 3: Keyswitches
If the user wants to set and unset the system with a Keyswitch:
• Wire a keyswitch to a zone
• Use Menu 32 to program the zone as a keyswitch type (KS). Note
that keyswitch zones do not belong to any particular Area.
• Use Menu 41 to assign Levels to individual keyswitch zones.
By using a 3 position keyswitch you can apply Levels to create Part Set - Off
- Full Set. For example: Part Set can be allocated to Level B, programmed
to set Area 01, 02, and 03. Full Set can be allocated to Level A, pro-
grammed to set Areas 01, 02, 03 and 04.
If you wish to use the LED on the keyswitch, use Menu 51 to program output
OP3 as either "Day" or "Level Set". See "5.Programming Reference - Menu
51".
Figure 23 shows the menus to use for programming keyswitches.
Use:
To:
Notes:
Assign keyswitch zone
type.
Menu 32
KS
Select Level
Select appropriate
keyswitch zone for level.
Assign keyswitch position.
Menu 41
For Fixed three position keyswitches
(zone KS select:
FULL to set Level with keyswitch in
"Full" position.
PART to set Level with keyswitch in
"Part" position.
For two position keyswitch select
FULL.
Assign output for
keyswitch LED
Menu 51
Day or Level Set.
Figure 23. Programming Example 3
808 sect 4 programming.p65
9/8/98, 10:27 AM