Attached Table 1 Multi-step speed command function description
Four multi-speed command terminals can be combined into 16 states, and these 16 states correspond to 16
command setting values. As shown in Table 1:
K4
K3
K2
K1
Command setting
Corresponding
parameters
OFF
OFF
OFF
OFF
Multi-step speed command 0
05-00
OFF
OFF
OFF
ON
Multi-step speed command 1
05-01
OFF
OFF
ON
OFF
Multi-step speed command 2
05-02
OFF
OFF
ON
ON
Multi-step speed command 3
05-03
OFF
ON
OFF
OFF
Multi-step speed command 4
05-04
OFF
ON
OFF
ON
Multi-step speed command 5
05-05
OFF
ON
ON
OFF
Multi-step speed command 6
05-06
OFF
ON
ON
ON
Multi-step speed command 7
05-07
ON
OFF
OFF
OFF
Multi-step speed command 8
05-08
ON
OFF
OFF
ON
Multi-step speed command 9
05-09
ON
OFF
ON
OFF
Multi-step speed command 10
05-10
ON
OFF
ON
ON
Multi-step speed command 11
05-11
ON
ON
OFF
OFF
Multi-step speed command 12
05-12
ON
ON
OFF
ON
Multi-step speed command 13
05-13
ON
ON
ON
OFF
Multi-step speed command 14
05-14
ON
ON
ON
ON
Multi-step speed command 15
05-15
When the frequency source is selected as multi-step speed, the parameters 100.0% of 05-00~05-15 correspond
to the maximum frequency max frequency 00-03. Multi-step speed command can not only be used as a multi-step
speed function, but also can be used as a given source of PID, or as a voltage source for V/f separation control to
meet the needs of switching between different given values.
Attached Table 2 Acceleration and deceleration time terminal function description
Terminal 2
Terminal 1
Acceleration or deceleration time selection
Corresponding parameters
OFF
OFF
Acceleration time 1
00-07,00-08
OFF
ON
Acceleration time 2
09-03,09-04
ON
OFF
Acceleration time 3
09-05,09-06
ON
ON
Acceleration time 4
09-07,09-08
04-08
MI Filter time
Factory setting
0.010s
Setting range 0.000s
~
1.000s
Set the software filtering time for the terminal state of the MI terminal. If the input terminal of the application
occasion is susceptible to interference and cause malfunctions, this parameter can be increased to enhance the
anti-interference ability. However, the increase of the filtering time will cause the response of the MI terminal to
become slow.
Содержание S3100E Series
Страница 1: ...S3100Eseries inverter General vector control PM User manual User manual ...
Страница 23: ...19 Size 3 Unit mm S3100E 2T5 5G 2T7 5G S3100E 4T7 5G 11P 4T22G Size 4 Unit mm S3100E 4T22G 30P 4T37G 45P ...
Страница 24: ...20 Size 5 Unit mm S3100E 4T45G 55P 4T110G Size 6 Unit mm S3100E 4T110G 132P 4T160G 185P ...
Страница 25: ...21 Size 7 Unit mm S3100E 4T185G 200P 4T220G Size 8 Unit mm S3100E 4T220G 250P 4T315G ...
Страница 26: ...22 Size 9 Unit mm S3100E 4T315G 355P 4T400G 450P Size 10 Unit mm S3100E 4T450G 500P 4T500G ...