![Savch S3100E Series Скачать руководство пользователя страница 40](http://html.mh-extra.com/html/savch/s3100e-series/s3100e-series_user-manual_1203759040.webp)
36
02 Vector control parameters
indicates that the parameters can be set during operation
Parame
ter
Parameter function
Setting range
Factory
setting
02-13
Excitation adjustment proportional
gain
0
~
60000
3000
02-14
Excitation adjustment integral gain 0
~
60000
500
02-15
Torque adjustment proportional
gain
0
~
60000
300
02-16
Torque adjustment integral gain
0
~
60000
500
02-17
Reserved
0
02-18
Field weakening mode of
synchronous motor
0,1,2
1
02-19
Field weakening gain of
synchronous motor
0~50
5
02-22
The upper limit of generating
torque becomes effective
0:Close
1:Open
0
02-23
Synchronous motor output voltage
upper limit margin
0%
~
50%
5%
02-24
Synchronous motor initial position
angle detection current
10%
~
180%
80%
02-25
Synchronous motor initial position
angle detection
0:Check every run
1:Not check
2:Power-on first run detection
0
02-36
Low speed excitation current
0
~
80%
30%
02-37
Low speed carrier frequency
0.8K
~
00-10
1.5K
02-43
Zero servo enabling
0
~
1
0
02-44
Switchover frequency
0.00~02-02
0.30Hz
02-45
Zero servo KP gain
1
~
100
10
02-46
Zero servo TI time
0.01s~10.00s
0.50s
02-49
Auto-tuning mode
0
,
1
,
2
0
02-51
Initial position compensation
angle
0.0
°
~360.0
0.0
Содержание S3100E Series
Страница 1: ...S3100Eseries inverter General vector control PM User manual User manual ...
Страница 23: ...19 Size 3 Unit mm S3100E 2T5 5G 2T7 5G S3100E 4T7 5G 11P 4T22G Size 4 Unit mm S3100E 4T22G 30P 4T37G 45P ...
Страница 24: ...20 Size 5 Unit mm S3100E 4T45G 55P 4T110G Size 6 Unit mm S3100E 4T110G 132P 4T160G 185P ...
Страница 25: ...21 Size 7 Unit mm S3100E 4T185G 200P 4T220G Size 8 Unit mm S3100E 4T220G 250P 4T315G ...
Страница 26: ...22 Size 9 Unit mm S3100E 4T315G 355P 4T400G 450P Size 10 Unit mm S3100E 4T450G 500P 4T500G ...