01 Motor control parameters
indicates that the parameters can be set during operation
Parame
ter
Parameter function
Setting range
Factory
setting
01-02
Motor rated power
0.1kW
~
1000.0kW
Type setting
01-03
Motor rated frequency
0.01Hz
~
max frequency
Type setting
01-04
Motor rated rotation speed
1rpm
~
65535rpm
Type setting
01-05
Motor rated voltage
1V
~
2000V
Type setting
01-06
Motor rated current
0.01A
~
655.35A(inverter power <=55kW)
0.1A
~
6553.5A(inverter power >55kW)
Type setting
01-12
Motor type selection
2:Permanent magnet synchronous motor
2
01-16
Stator resistance of synchronous
motor
0.001Ω
~
65.535Ω(inverter power<=55kW)
0.0001Ω
~
6.5535Ω(inverter power >55kW)
Type setting
01-17
D-axis inductance of synchronous
motor
0.1mH
~
6553.5mH(inverter power<=55kW)
0.01mH
~
655.35mH(inverter power>55kW)
Type setting
01-18
Q-axis inductance of synchronous
motor
0.1mH
~
6553.5mH(inverter power <=55kW)
0.01mH
~
655.35mH(inverter power >55kW)
Type setting
01-20
Back-EMF coefficient of
synchronous motor
0.1V~6553.5V
Type setting
02 Vector control parameters
indicates that the parameters can be set during operation
Parame
ter
Parameter function
Setting range
Factory
setting
02-00
Speed loop proportional gain 1
1
~
100
20
02-01
Speed loop integration time 1
0.01s
~
10.00s
0.50s
02-02
Switching frequency 1
0.00
~
02-05
5.00Hz
02-03
Speed loop proportional gain 2
1
~
100
20
02-04
Speed loop integration time 2
0.01s
~
10.00s
1.00s
02-05
Switching frequency 2
02-02
~
max frequency
10.00Hz
02-06
Vector control slip gain
50%
~
200%
100%
02-07
Digital setting of torque upper limit
in speed control mode
0.0%
~
200.0%
150.0%
02-08
Speed loop filter time constant
0
~
31
28
02-09
Vector control over excitation gain 0
~
200
64
02-10
Torque upper limit source in
speed control mode
0:Parameter 02-07 setting
1:AVI1
2:AVI2 / ACI
3:reserved
4:PULSE pulse setting
5:
Communication setting
6:MIN (AVI1, AVI2 / ACI)
7:MAX (AVI1, AVI2 / ACI)
The full scale of the 1-7 option corresponds
to 02-07
0
Содержание S3100E Series
Страница 1: ...S3100Eseries inverter General vector control PM User manual User manual ...
Страница 23: ...19 Size 3 Unit mm S3100E 2T5 5G 2T7 5G S3100E 4T7 5G 11P 4T22G Size 4 Unit mm S3100E 4T22G 30P 4T37G 45P ...
Страница 24: ...20 Size 5 Unit mm S3100E 4T45G 55P 4T110G Size 6 Unit mm S3100E 4T110G 132P 4T160G 185P ...
Страница 25: ...21 Size 7 Unit mm S3100E 4T185G 200P 4T220G Size 8 Unit mm S3100E 4T220G 250P 4T315G ...
Страница 26: ...22 Size 9 Unit mm S3100E 4T315G 355P 4T400G 450P Size 10 Unit mm S3100E 4T450G 500P 4T500G ...