Communication error message response:
When a communication frame is detected as an error, the slave responds with a one-byte error code that defines
the cause of the error. After the main device application receives an error code response, the typical process is to
resend the message or make a command change for the corresponding error.
Communication error code definition:
Communication error home
address
Wrong code definition
5001H
0000:No fault
0001:Password error
0002:Command code error
0003:CRC checking error
0004:Invalid address
0005:Invalid parameters
0006:Parameter change invalid
0007:System locked
0008:Being EEPROM operation
13 Wobble Frequency Counting Parameters
The wobble frequency function is suitable for textile, chemical fiber and other industries, as well as occasions
requiring traversing and winding functions.The wobble frequency function means that the output frequency of the
inverter wobble up and down with the set frequency as the center. The trajectory of the running frequency on the
time axis is shown in Figure 5-29. The wobble amplitude is set by 13-00 and 13-01. When 13 When -01 is set to 0,
that is, the wobble amplitude is 0, the wobble frequency has no effect.
Output frequency(Hz)
Time(t)
Center frequency Fset
Wobble cycle
Wobble amplitude
Aw=Fest x 13-01
Textile jump frequency
=Aw X 13-02
Triangle
wave rise
time
Accelerate by
acceleration
time
Decelerate by
deceleration
time
Upper limit of
wobble frequency
Lower limit of
wobble frequency
Run command
+Aw
-Aw
Figure 5-29 Schematic diagram of wobble frequency operation
13-00
Wobble setting mode
Factory setting
0
Setting range
0
Relative to center frequency
1
Relative to Max frequency
Содержание S3100E Series
Страница 1: ...S3100Eseries inverter General vector control PM User manual User manual ...
Страница 23: ...19 Size 3 Unit mm S3100E 2T5 5G 2T7 5G S3100E 4T7 5G 11P 4T22G Size 4 Unit mm S3100E 4T22G 30P 4T37G 45P ...
Страница 24: ...20 Size 5 Unit mm S3100E 4T45G 55P 4T110G Size 6 Unit mm S3100E 4T110G 132P 4T160G 185P ...
Страница 25: ...21 Size 7 Unit mm S3100E 4T185G 200P 4T220G Size 8 Unit mm S3100E 4T220G 250P 4T315G ...
Страница 26: ...22 Size 9 Unit mm S3100E 4T315G 355P 4T400G 450P Size 10 Unit mm S3100E 4T450G 500P 4T500G ...