3.2.2 Failure Resetting
When the inverter receiveds a fault, it will display the relative fault information. User can reset the fault by the
STOP/RESET key on keyboard or terminal function (group 04). The inverter will be in standby state after fault
resetting. If the user doesn’t reset when the inverter receiveds a fault, it will be in running protection state and
unable to be operated.
3.2.3 Motor Parameter Self-learning
The nameplate parameter of motor is needed to be input accurately when selecting open loop vector control.
The inverter will match the standard motor parameter according to the nameplate parameters. To obtain the
excellent control performance, it is recommended to carry out the motor parameters self-learning, the operation
step as follows.
First, select the running reference channel (00-00) as the keyboard reference channel .
Then input following parameters according to motor actual parameters.
01-02:motor rated power
01-03:motor rated frequency
01-04:motor rated rotation speed
01-05:motor rated voltage
01-06:motor rated current
During the self-learning process, select the 01-01 self-learning mode and press the DATA / ENT key, the
keyboard will display TUNE, and then press the keyboard RUN key, the inverter will drive the motor to perform
self-learning for about 2 minutes, the display information disappears, and returns Normal display status indicates
that the motor parameter self-learning is completed.
Note:During the process of self-learning, the motor must to be uncoupled from load. Otherwise, incorrect
parameters would be obtained.
3.2.4 Password Setting
S3100E series inverters provide user password protection function. When 08-00 is set to non-zero, it is the
user password, exit the function code editing state, the password protection is effective, and press PRG / ESC
key again to enter the function code editing state, "-----" Is displayed. After pressing the DATA / ENT key, the
"00000" user password input interface is displayed. The operator must enter the user password correctly,
otherwise he cannot enter.
To cancel the password protection function, set 08-00 to 0. The user password does not protect the
parameters in the shortcut menu.
Exit the function code editing state, the user password is locked immediately, and the user password is
required to enter again.
Содержание S3100E Series
Страница 1: ...S3100Eseries inverter General vector control PM User manual User manual ...
Страница 23: ...19 Size 3 Unit mm S3100E 2T5 5G 2T7 5G S3100E 4T7 5G 11P 4T22G Size 4 Unit mm S3100E 4T22G 30P 4T37G 45P ...
Страница 24: ...20 Size 5 Unit mm S3100E 4T45G 55P 4T110G Size 6 Unit mm S3100E 4T110G 132P 4T160G 185P ...
Страница 25: ...21 Size 7 Unit mm S3100E 4T185G 200P 4T220G Size 8 Unit mm S3100E 4T220G 250P 4T315G ...
Страница 26: ...22 Size 9 Unit mm S3100E 4T315G 355P 4T400G 450P Size 10 Unit mm S3100E 4T450G 500P 4T500G ...